SERIAL CABLE INSTALLATION, CONT.
CURRENT Cardinal Indicators 20mA Current Loop Connections
225
PORT 0 (ACTIVE)
P20,10
P20,8
PORT 1 (ACTIVE)
P20, 3
P20, 4
JUMPER
P20, 5 to P20, 8
PORT 2 (ACTIVE)
P16, 1
P16, 2
JUMPER
P16, 3 to P16, 9
825
PORT 2 (ACTIVE)
P21, 2
P21, 5
J3 INSTALLED
J7 SHUNT:20mA
18
SB600
P6, CLRX+
P6, CLRX-
SB600
P6, CLRX+
P6, CLRX-
n/c
SB600
P6, CLRX+
P6, CLRX-
n/c
SB600
P6, CLRX+
P6, CLRX-
n/c
3601-0756-0M Rev D • SB600
PORT 1 (PASSIVE)
P20, 4
P20, 5
n/c
PORT 2 (PASSIVE)
P16, 2
P16, 3
n/c
PORT 2 (PASSIVE)
P21, 1
P21, 2
J3 REMOVED
J7 SHUNT:20mA
SB600
P6, CLRX-
P6, GND
JUMPER
CS2 to CLRX+
SB600
P6, CLRX-
P6, GND
JUMPER
CS2 to CLRX+
SB600
P6, CLRX-
P6, GND
JUMPER
CS2 to CLRX+