Download Print this page

Shower Mixer Installation - Gentec Single Lever Basin Mixer GPN1000 Installation Manual

Stainless steel single lever mixers

Advertisement

SHOWER MIXERS
GPN4000, GPN4000D
1.
Mount the box (9) into the wall.
2.
Locate the main valve (7) into the box (9).
Fix the shower mixer (7) so that the outer
sleeve protrudes at least 15mm out from
the finished wall with the shower outlet
vertical at 90 degrees. The cold inlet is to
be on the right and parallel with the hot
inlet on the left.
3.
Connect hot (left) and cold (right) water
on each side of the mixer valve.
All screwed fittings connected to the
valve must be easily dismantled so the
main valve can be removed.
4.
Ensure the box (9) is flush with the
finished wall this includes tiles ,
waterproofing, etc
5.
To finish off the installation, fit rubber (5)
to the stainless-steel front cover plate (4)
*Service inspections at regular intervals especially in high usage areas will assist in optimising
the operational life of the product.
www.gentecaustralia.com.au
6.
Push the black frame on to the
box (9) using 4 screws
and
tighten
7.
Put on the handle (1). Correct position
is with the end pointing down and
secure it with the 2.5mm Allen key
provided
in
a clock-wise
Important Information
We do not recommend dismantling the
internal parts of the shower set.
(8) provided
against
the
wall.
direction.
10

Advertisement

loading