5
SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Outdoor Unit
RAV-GP561ATW*
No.
1
Compressor
2
Outdoor fan motor
3
4-way valve coil
4
PMV coil
5
High pressure switch
6
Compressor thermostat (Protection)
7
Reactor
8
P.C. board
9
Outdoor temp. sensor (TO sensor)
10 Discharge temp. sensor (TD sensor)
11 Suction temp. sensor (TS sensor)
12 Heat exchanger temp. sensor (TE sensor)
13 Heat exchanger mid. temp. sensor (TL sensor)
14 Fuse (Inverter, input (Current protect))
15 Fuse (Switching power (Protect))
16 Fuse (Indoor unit, input (Current protect))
RAV-GP801ATW*
No.
1
Compressor
2
Outdoor fan motor
3
4-way valve coil
4
PMV coil
5
High pressure switch
6
Compressor thermostat
7
Reactor
8
P.C. board
9
P.C. board (LED display)
10 Outdoor temp. sensor (TO sensor)
11 Discharge temp. sensor (TD sensor)
12 Suction temp. sensor (TS sensor)
13 Heat exchanger temp. sensor (TE sensor)
14 Heat exchanger mid. temp. sensor (TL sensor)
15 Fuse (Mounted on P.C. board, MCC-1705)
16 Fuse (Mounted on P.C. board, MCC-1705)
17 Fuse (Mounted on P.C. board, MCC-1705)
18 Relay
Parts name
Parts name
Type
DX150A1T-21F
ICF-140-A43-1
STF-H01AZ1724A1
PQ-M10012-000313
ACB-4UB154W
CS-12AL
CH-102-Z-T
MCC-1768
—
—
—
—
—
—
—
—
Type
NX220A1F-20N
ICF-280-A60-1
STF-H01AZ1724A1
UKV-A040
ACB-4UB83W
US-622
CH-101
MCC-1705
MCC-1646
—
—
—
—
—
GDT250V25A-A
—
—
—
40
Specifications
—
DC140 V, 43 W
DC12 V
DC12 V
OFF: 4.15 Mpa
OFF: 125 ± 4°C, ON: 90 ± 5°C
18 mH, 16 A
—
10 kΩ at 25°C
1.905 kΩ at 120°C
10 kΩ at 25°C
10 kΩ at 25°C
3.3 kΩ at 100°C
25 A, AC 250 V
3.15 A, AC 250 V
6.3 A, AC 250 V
Specifications
—
DC280 V, 60 W
DC12 V
DC12 V
OFF: 4.15 MPa
OFF: 125 ± 4˚C, ON: 90 ± 5˚C
10 mH, 20 A
—
—
10 kΩ at 25˚C
1.905 kΩ at 120˚C
10 kΩ at 25˚C
10 kΩ at 25˚C
1.905 kΩ at 120˚C
25 A, 250 V
3.15 A, 250 V
10 A, 250 V
20 A, 250 V