Ambient temperature for operation
Storage temperature
4.1
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Sound (power) level (L
Uncertainty for the sound power level
(K
)
WA
Emission sound pressure level (L
Uncertainty for the sound pressure
level (K
)
pA
Total vibration
Vibration emission value when tighten-
ing screws/bolts and nuts of the maxi-
mum permitted size (a
Uncertainty for tightening
screws/bolts and nuts of the maximum
permitted size
4.2
Setting the torque
The torque is selected by way of the torque selector button.
Model SID ...
SID 14­A
SID 22­A
Torque
*2072653*
SID 14­A
)
94 dB(A)
WA
3 dB(A)
)
83 dB(A)
pA
3 dB(A)
SID 14­A
7.5 m/s²
)
h
1.5 m/s²
Model
SID 14­A
Setting I
50 Nm
Setting II
100 Nm
Setting III
150 Nm
2072653
SID 22­A
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
SIW 14­A
94 dB(A)
3 dB(A)
83 dB(A)
3 dB(A)
SIW 14­A
7.5 m/s²
1.5 m/s²
SIW 22­A
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
SID 22­A
SIW 22­A
97 dB(A)
97 dB(A)
3 dB(A)
3 dB(A)
86 dB(A)
86 dB(A)
3 dB(A)
3 dB(A)
SID 22­A
SIW 22­A
11 m/s²
11 m/s²
1.5 m/s²
1.5 m/s²
SID 22­A
60 Nm
110 Nm
165 Nm