Operating Instructions; Preparing For Measuring - WatchGas BAT-1 Manual

Breathing air quality test kit
Hide thumbs Also See for BAT-1:
Table of Contents

Advertisement

5. Operating Instructions

.

5.1 Preparing for Measuring

First follow these steps before performing the test in 5.2 or 5.3.
First it is important to determine the detection limit of the oil typ using table 7.
Determine sampling time according the threshold value to be detected using table 8.
Table 7: Detection limits
Oil
Mobil Rarus 425
Mobil Rarus 427
Mobil Rarus 827
Liqui Moly LM 750 SAE 40
Dräger U10822/U10823
Other oils on request
Table 8: Measurement time for evaluated reference value
Evaluated
Detection
detection limit 0.1
limit
mg/m3
5 µg
25 min
10 µg
50 min
15 µg
75 min
20 µg
100 min
25 µg
125 min
30 µg
150 min
40 µg
-
50 µg
-
Clean valve of compressed gas cylinders or charging connections of compressor with brief burst
of air.
Figure 2: 200 & 300 bar compressor adapters
WatchGas B.V.
Detection
limit
5 µg
10 µg
25 µg
40 µg
40 µg
-
Evaluated
detection limit 0.3
mg/m3
8 min
17 min
25 min
33 min
42 min
50 min
67 min
83 min
Klaverbaan 121, 2908KD, Capelle a/d IJssel, The Netherlands
T: +31 (0) 85 0187709
info@watchgas.eu
Evaluated
detection limit 0.5
Evaluated detection
mg/m3
limit 1.0 mg/m3
5 min
3 min
10 min
5 min
15 min
8 min
20 min
10 min
25 min
13 min
30 min
15 min
40 min
20 min
50 min
25 min
www.watchgas.eu