WatchGas AirWatch MK1.2 User Manual
Hide thumbs Also See for AirWatch MK1.2:

Advertisement

Quick Links

D e t e c t i o n
USER MANUAL
AirWatch
MK1.2
www.watchgas.eu
www.watchgas.eu

Advertisement

Table of Contents
loading

Summary of Contents for WatchGas AirWatch MK1.2

  • Page 1 D e t e c t i o n USER MANUAL AirWatch MK1.2 www.watchgas.eu www.watchgas.eu...
  • Page 2: Table Of Contents

    AirWatch MK 1.2 User Manual D e t e c t i o n Contents Contents Description Warning Caution Important Product Overview Description Mode Backup Battery Wireless Version AirWatch Receiver AirWatch Repeater Beacon Sounder Software Application Safety And Signalling AirWatch Signalling Transportation Storage, Assembly and Installation Various Parts And Highlights Operation...
  • Page 3: Description

    STATIC ELECTRICITY DANGER: only clean the device with a moist cloth. • This manual should be read by everyone who operates or monitors the watchgas gas detection system. Only personnel who have been fully trained by are authorised to Install, Set-up, Service, and Test, Repair, or Recondition the system.
  • Page 4: Product Overview

    AirWatch MK 1.2 User Manual D e t e c t i o n 1. Product Overview AIRWATCH COMPONENTS Status LED Green Status LED Wireless Blue Status LED Red SD Card Slot LCD display On/Off and contact A (with use of magnetic key) Serial Number Alarm reset and contact B (with use of magnetic key) Gas Inlet...
  • Page 5: Description Mode

    AirWatch for up to 60 minutes. This time can be adjusted with the configuration software (which can be found on the download page of www.watchgas.eu). With the optional wireless function the AirWatch sends a signal when it switches from the external power supply to the backup battery.
  • Page 6: Airwatch Receiver

    AirWatch MK 1.2 User Manual D e t e c t i o n 2.3 AIRWATCH RECEIVER It is therefore possible to turn off up to 50 machines at once when an alarm occurs. The optional wireless communication functions at a frequency of 2.4 GHz within a mesh network.
  • Page 7: Software

    D e t e c t i o n 2.6 SOFTWARE The specially developed monitoring software for the Wireless AirWatch, which you can find on www.WatchGas.eu, can be used for many different purposes, for example in process control rooms, CCTV monitoring, and issuing work permits. The real-time data from the AirWatches enters via an additional PC or laptop.
  • Page 8: Safety And Signalling

    AirWatch MK 1.2 User Manual D e t e c t i o n 3. Safety And Signalling Read the manual and quick start guide before use. The applicable regulations must be complied with at all times when carrying out repairs on these devices or parts. Repairs to the device may be carried out only by trained staff in accordance with the AirWatch maintenance instructions.
  • Page 9: Transportation Storage, Assembly And Installation

    Turn on the AirWatch and let it run through the boot menu. See Gas Inlet page 11. • Carry out a fresh-air calibration, and a bump test. Bottom of AirWatch with Gas inlet, Modbus, 7Pins DC Power in Relay out, Gas outlet & DC Desktom (Maintenance only) www.watchgas.eu...
  • Page 10: Various Parts And Highlights

    The AirWatch has a delay time of 0-60 minutes (this can be configured with configuration software, which you can find on www.watchgas.eu). With a delay time, it will continue to measure after the machine has been turned off and while the engine and exhaust remain hot.
  • Page 11 AirWatch MK 1.2 User Manual D e t e c t i o n D e t e c t i o n www.watchgas.eu...
  • Page 12: Operation

    AirWatch MK 1.2 User Manual D e t e c t i o n 6. Operation 6.1 HOW TO USE MAGNET KEYS When turning on the AirWatch, the cable between the AirWatch and the machine must be connected. When the boot menu has been completed, the red LED will come on and the green LED will start flashing.
  • Page 13: Flow Fault Adjustment

    NOTE: A span calibration must only be carried out by trained personnel. If this is not done correctly the device To adjust flow fault upper and lower settings follow the will no longer function properly. This may result in procedure below entering the manual menu. dangerous situations. www.watchgas.eu...
  • Page 14: Bump

    AirWatch MK 1.2 User Manual D e t e c t i o n 6.5 BUMP Select ‘Bump’ in order to test the sensors. The AirWatch will ask you to apply the gas. Please confirm that you test gas contains the same concentration as the span values of the AirWatch, the Bump Test algorythm expects the same concentration to be applied.
  • Page 15: Relay Settings

    The other 2 relays you can use by adding a cable gland (0.5mm 2 to 2.5mm 2). Basic Relay Settings: in basic configuration Relay 2 will be setup as a energised relay. 7 Pins DC MIN GND 1 DC MIN 10-30V DC 2 DC 10-30V 5 6 3 2 7-Pins Connector Visual. www.watchgas.eu...
  • Page 16: Configuration Software

    To setup all features en functions of the AirWatch please download and install our configuration software, which is available on our WatchGas website. With the configuration software you can change the alarm levels, setup pin codes, select sound and colors for the optional Beacon Sounder, setup the relays and many more options.
  • Page 17: Operation And Troubleshooting

    ‘alarm reset’ to reset the alarm. Bump Fail. Incorrect bump gas, sensors unstable. Repeat bump Bump result: FAIL test. If the problem occurs repeatedly, contact WatchGas. 00 0.0 20.9 Invalid Configuration. Try to reconfigure your device with the...
  • Page 18: User Maintanance

    Turn the AirWatch on and carry out a fresh air calibration. • After the AirWatch has been started, carry out a pump test.Contact your supplier or WatchGas to obtain bump test Highlighted for more equipment, flow regulators, bump gas cylinders and hoses. Also see chapter 6, Various Parts information.
  • Page 19: Spare Parts And Accessoiries

    Connector female 6 pins DC positive 9/36vDC Bridged DC negative Other types of sensors on request. Bridged Amphenol female 3 pins Bridged Bridged Modbus B Modbus A Modbus Connector assembly Pin out of the 3 pins modbus connector P/N: 501138 www.watchgas.eu...
  • Page 20: Specifications

    Stand-alone via cable type 1 or 2, RS 485 or Wireless via 2.4 GHz ISM band, complies communication with the IEEE 802.15.4 standard and 3/4G with the WatchGas remote online platform Range wireless 300 meters (with line of sight) (2.4 GHz) Communication Max.
  • Page 21: Limited Warranty

    In the event that a product should fail to perform up to manufacturer specifications during the applicable war- ranty period, please contact the product’s authorized reseller or WATCHGAS service center at +31 (0)85 01 87 709 for repair/return information.