Summary of Contents for WatchGas PDM

  • Page 1 D e t e c t i o n User Manual PDM Single Gas Detector www.watchgas.nl...
  • Page 2: Table Of Contents

    PDM Single Gas Detector User Manual D e t e c t i o n D e t e c t i o n Contents Contents Description Warning Caution Product Overview Activation Check Activation Date Serial Number Getting 24 months of use...
  • Page 3: Description

    D e t e c t i o n Description The PDM is a portable multigas monitor designed to warn the user about the presence of dangerous concentrations of oxygen, combustible, or toxic gases in the atmosphere. It is simple to operate. The PDM alerts the workers to danger through acoustic alarm, flashing LEDs, and vibration when the concentration exceeds the safety gas levels.
  • Page 4: Product Overview

    PDM Single Gas Detector User Manual D e t e c t i o n D e t e c t i o n 1. Product Overview DETECTOR COMPONENTS Gas sensor Gas type sticker LCD display Beeper port Alarm LEDs...
  • Page 5: Activation

    WG stands for WatchGas. I = 2018, J = 2019, K = 2020 etc. 2.3 GETTING 24 MONTHS OF USE The battery and the sensor of the PDM are not replaceable. Make sure the battery doesn´t get drained before the 24 months are over. To reach 24 months of use: •...
  • Page 6: Mode

    ) ->Low alarm set point ->High alarm set point -> Firmware version -> Calibration Concentration At the last step, if you press the key or do not push any button for a second, the PDM will return to Detection Mode.
  • Page 7: Alarms / Battery / Test Failure Display

    LEDs, and beep. To stop alarms, evacuate immediately to a clean air location. When bump test or calibration failed, will be displayed and the PDM will beep intermittently. Alarm Alarm standard...
  • Page 8: Alarm Set Points

    (99,9% N 4. Event Log Last 30 events are stored on the PDM. Once 30 events are stored, the oldest log events get overwritten. Stored log events can be transferred via WatchGas-IR Link. Each alarm event is recorded as follows:...
  • Page 9: Calibration

    User Manual Single Gas Detector PDM D e t e c t i o n D e t e c t i o n 5. Calibration Caution Initial calibration is performed on all devices prior to shipment. Once received, calibration should be regularly depending on frequency of use.
  • Page 10: Standard Gas Calibration

    In the standard calibration mode , press the key for a second to toggle fresh air calibration, standard calibration, and ESC. In the ESC mode, press the key for 3 seconds, the PDM will get out of the calibration mode and return to detection mode.
  • Page 11: Self Test & Bump Test

    6. Self Test & Bump test 6.1 SELF TEST The default interval of the Self-Test is 20hr, meaning the PDM will ask for a self test after each 20 hours of use. The interval is configurable via IR-Link between 8~20 hours. The self test can also be switched off via IR-Link.
  • Page 12: Specifications

    PDM Single Gas Detector User Manual D e t e c t i o n D e t e c t i o n 7. Specifications Model SO₂ H₂ Detectable gas ranges 0-30%Vol 0-500ppm 0-100ppm 0-200ppm 0-100ppm 0-1000ppm SO₂ H₂...
  • Page 13: Certificates

    User Manual Single Gas Detector PDM D e t e c t i o n D e t e c t i o n 8. Certificates Intrinsic Safety: The detector is in conformity of the following standards IECEx: Ex ia IIC T4 Ga 1 IECEx KTL 15.0018...
  • Page 14: Limited Warranty

    D e t e c t i o n 9. Limited Warranty WATCHGAS warrants this product to be free of defects in workmanship and materials-under normal use and service-for two years from the date of purchase from the manufacturer or from the product’s authorized reseller.