  • Page 1 D e t e c t i o n Quick Start Guide POLI Multi Gas Detector...
  • Page 2 Warnings Read Before Operating The full POLI User’s Guide must be carefully read by all individuals who have or will have the responsibility of using, maintaining or servicing this product. The product will perform as designed only if it is used, maintained and serviced in accordance with the manufacturer’s instructions.
  • Page 3: User Interface

    • Utilisez uniquement le numéro de pièce de la batterie au lithium WatchGas M004-3002-W00 (12.01.09.0001). • Cet instrument n’a pas été testé dans une atmosphère explosive gaz / air ayant une concentration en oxygène supérieure à 21%.
  • Page 4: Turning The Unit On

    Charging Always fully charge the battery before use. Plug the charger into the bottom of the POLI. The battery icon on the LCD shows the charge status. During active charging, the icon cycles from empty to full and a yel- low alarm light remains on, which switches to green when completely charged.
  • Page 5: Configuration Mode

    Other values like STEL, TWA, Peak , Min, Date, LEL gas, etc. can be checked by pressing the Right Key to cycle through these screens one by one. The Left “Test” key check alarm function. Two text and symbol boxes at the LCD bottom are mapped to the Left [+/OK] and Right [ / ] keys.
  • Page 6: Exit Config Mode

    Config Mode Menu • CALIBRATION: Calibration, Bump, Set span value • MEASURE: Enable/Disable sensors, Gas units • ALARM: Set alarm limits, Man-Down info, etc. • DATALOG: Clear data, Set interval, Select sensors • MONITOR SET-UP: LCD, Pump speed, Language • WIRELESS: Wireless on/off or Register •...
  • Page 7 • To save and exit: Press the Right Key until “Done “ appears in the bot- tom-left corner, then press Left to exit. If changes have been made, there will be a message to confirm saving the new values. Press “Yes” to save, “No” to discard. Bump Test A bump test is a quick 30-second check if the sen- sors and alarms functioning, without doing a precise...
  • Page 8: Fresh Air Calibration

    Fresh Air Calibration Zero calibration sets the baseline for the sensor and is done in normal fresh air or other clean air source. • Enter fresh air calibration: • Config Mode Calibration Fresh Air Calib. • Select sensors to be zeroed in the same manner as described for Bump testing.
  • Page 9: Maintenance And Service

    For pumped units, replace the inlet filter a regular basis, especially when used in high-dust environments. For battery or sensor replacement and other maintenance or services, please contact WatchGas or refer to the User Manual. D e t e c t i o n WatchGas Sextantstraat 61...