NOTES WHILE USING ZERO EXPORT FUNCTION
For your safety and the operation of limiter function of the inverter, we put forward the following suggestions and
precautions:
7.6
HOW TO BROWSE THE LOAD POWER OF YOUR PV GRID-TIE PLANT ON MONITORING PLATFORM?
If you want to browse load power of the system and how much energy (KWH) does it export to grid (inverter output
power is used to power the load rstly and then the surplus energy will feed into grid). You also need to connect the
meter according to above diagram. After the connection completed successfully, the inverter will show the load power
on the LCD. But please don't setup "Meter ON". Also, you will be able to browse the load power on the monitoring
platform. The plant setting method as below description.
Firstly, go to the solarman platform (https://pro.solarmanpv.com, this link is for solarman distributor account; or
https://home.solarmanpv.com, this link is for solarman end user account;) plant home page and click "edit".
Hymon Fotowoltaika Sp z o.o.
ul. Dojazd 16A 33-100 Tarnów
Warning:
Under zero export mode we strongly recommend that the two PV arrays are
formed by the same number of PV panels of the same size, which will make the
inverter more responsive to limit the power.
Safety Hint:
While the utility power is negative and inverter has no output power, that means
the orientation of the current sensor is wrong, please turn o the inverter and
change orientation of the current sensor.
(when using SUN limiter, the arrow of current sensor points to the load)
High Temperature Hazard:
When using SUN limiter, the current sensor of limiter function needs to be
clamped on the re line of the grid connected to the inverter, otherwise inverter
cannot able to normal operate.