4. Handling Procedure
Charger
Information display window
"Info.Key" change button
On
80%
100%
Equalizing Charging
Initial Charging
Power supply switch
Power supply cable
Before charging
Hour meter
(Operation time integrating meter)
Charge capacity (Ah)
Lit during charging
Lit in green: 60% charged
Lit in red: 80% charged
Lit: Completion of charging
Lit: During equalizing charging
Lit: During initial charging
(This lamp is inactive because the battery is charged before shipment.)
Check the residual charge level.
Check the residual charge level with the battery discharge meter on the
vehicle body.
To check the residual charge level, follow the procedure below:
(1) Turn ON the key switch.
(2)
The lamp of the battery discharge meter lights. Check the charge level
by the lamp lit position.
  位 置 で 充 電 内 容 を 確 認 し て 下 さ い 。
0
Charge the battery immediately.
The indicator lamps indicate contents of the
information display window and fault of the
charger.
A
Charge current (A)
Ah
I.F
Query value
Charge cable
1/2
Charged
Insufficient charging
V
Battery voltage (V)
H
Charge time (H)
Lit: Fault of charger
Blinking:
Overheating of charger
   
Output contact failure