Electrical Box Temperature Rise - Daikin Floor Standing Type F-Series Service Manual

Inverter pair
Table of Contents

Advertisement

Troubleshooting

4.21 Electrical Box Temperature Rise

L3
Remote
Controller
Display
Method of
An electrical box temperature rise is detected by checking the radiation fin thermistor with the
Malfunction
compressor off.
Detection
Malfunction
Decision
Conditions
RK(X)S25/35F2V1B, RK(X)S25/35G2V1B
RK(X)S25/35G2V1B9
RK(X)S50F2V1B, RK(X)S50G2V1B
Supposed
Causes
113
With the compressor off, the radiation fin temperature is above
The error is cleared when the radiation fin temperature drops below
To cool the electrical components, the outdoor fan starts when the radiation fin temperature
rises above °C and stops when it drops below
Defective outdoor fan motor
Short circuit
Defective radiation fin thermistor
Disconnection of connector
Defective outdoor unit PCB
°C.
°C.
°C.
(°C)
(°C)
80
70
80
98
75
83
95
80
85
Service Diagnosis
SiBE06-708_A
(°C)

Hide quick links: