Removal Of Reactor / Partition Plate - Daikin Floor Standing Type F-Series Service Manual

Inverter pair
Table of Contents

Advertisement

Outdoor Unit - RK(X)S25/35G2V1B9
4.4

Removal of Reactor / Partition Plate

Procedure
Step
1. Remove the reactor.
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
Remove the 2 screws.
1
223
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Reactor
(R11879)
(R11880)
Partition plate
(R12273)
SiBE06-708_A
Points
Preparation
Remove the outer panels
according to the "Removal of
Outer Panels / Fan Motor".
Remove the electrical box
according to the "Removal of
Electrical Box".
Removal Procedure