5. Outdoor Unit - RK(X)S50F2V1B, RK(X)S50G2V1B

5.1

Removal of Outer Panels

Procedure
Step
1. Remove the panels.
Remove the 4 screws
1
and lift the top panel.
Remove the 4 screws
2
and remove the
discharge grille.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Discharge grille

Outdoor Unit - RK(X)S50F2V1B, RK(X)S50G2V1B

Top panel
(R12283)
(R12315)
(R5245)
Points
Take care not to cut your
finger by the fins of the
outdoor heat exchanger.
Slide the discharge grille
upwards and remove it.