16. Press Scroll Keys as necessary to increase (Scroll
Up Key) or decrease (Scroll Down Key) the Upper
Temperature Limit value.
17. Press and release the Tip Temperature Set Key to
store the displayed value into memory. The Digital
Readout will now display "C-1"
If you do not wish to recalibrate for readout
accuracy, press the Tip Temperature Offset Key
and perform steps 12 through 17. After all channels
have been calibrated, you may exit the Calibration
Mode by pressing and releasing the Tip
Temperature Offset key again.
18. Unplug the handpiece connected to the Current
Channel and plug in the #1 Calibration
Assembly.
19. Press and release the Tip Temperature Set
Key. The Digital Readout will flash (- - - " to
indicate that the system microprocessor circuitry
is recalibrating one aspect of the system circuitry,
"C-2" will now be displayed.