7 Periodic maintenance / 7.4 Cleaning the filter silencer
7.4

Cleaning the filter silencer

7.4.1
Variant: Filter silencer with connecting rod
Fig. 20: Cleaning the filter silencer
81135
Filter silencer body
81136
Absorption segment
81137
Sheet-metal covering
81265
Filter ring (if present)
If present: Clean the filter ring (81265)
Remove the filter ring.
u
Clean the filter ring as required or every 500 hours of operation, and replace it after the
u
fifth cleaning process at the latest.
Contamination of the filter ring depends on the degree of purity of the sucked-in air.
Rinse the filter ring with water and mild detergent or, in the case of heavy contamination,
u
soak and carefully push through. Rinse in cold water. Avoid high mechanical loads (water
jet).
Let the filter ring dry completely before assembling.
u
Dirty water and mild detergent must be disposed of in compliance with locally applicable
u
regulations.