Features
Dimensions (Front and Side View)
Speaker
Drain Hole
Call Button
Microphone
Hole
Terminal Block Connections
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
3
4
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
RTFM Button
RTFM button (SW1)
© 2022, CyberData Corporation, ALL RIGHTS RESERVED
7.480 [190.00]
Dimensions are in Inches [Millimeters]
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws
Wire (IN)
Tin Leads
Approx. 1/4" or
6mm
8
Terminal Block
can accept 16 AWG wire
When the device is operational and linked to a network, you
can use the Reset Test Function Management (RTFM) but-
ton (SW1 [see picture]) to announce the device's IP
address or restore the device to the factory
default settings.
To announce the device's current IP address:
•
Press and release the RTFM button within a five
second window.
Note
The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
IPv4 Link Local if a DHCP server is not present).
To restore the device to factory default settings:
•
Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
restoring the factory default settings.
931560F
Dimensions (Rear View and Mounting Holes)
2.284 [58.01]
Wall Mounting
Note: To mount the device, use methods
compliant with local electrical codes.
1
Note: More installation and mounting information
is illustrated in the Operations Guide.
SIP Outdoor Intercom with Keypad
Torx key
Faceplate mounting
Torx security screw
GENERAL ALERT
Quick Reference
Quick Reference
5.118 [130.00]
4.249 [107.93]
Ø0.876 [Ø22.25]
2.559 [65.00]
0.869 [22.07]
0.000 [0.00]
Dimensions are in inches [millimeters]
Note: For flush mount installations, purchase the 011442 Flush
Mount Kit, 2x (sold separately). For more information, go to:
https://www.cyberdata.net/products/011442
Apply RTV Silicone Sealant Around Mounting Holes and
Backside Perimeter of Backbox and Weather Shroud
Cables
create service loop
1/4"
anchor screw
to J1
J1
*
Network and Ground cables
through side Conduit Hole
with Compression connector
1/2" EMT
Compression
connector
with
sealing locknut
(Sold separately)
1/2" EMT
Conduit
Caution
Equipment Hazard: Do not use an electric or power screwdriver to fasten the face plate and PCB assembly to
the gang box. To prevent over-torque damage to the gasket, do not apply more than 10 inch-pounds force.
Over-torquing will cause the gasket to tear, risk moisture intrusion, and effectively void the manufacturer's
warranty.
931560F
Ø0.280 [Ø7.11]
(4 Places)
1/4" Concrete
Wall Anchor
Weather Shroud
011215 Outdoor Shroud, 2X
(Sold separately)
Ground Wire
Remove hole plug assembly then
Network Cable
Install it onto the
rear conduit hole
*
(All Cables, Fasteners, Sealant and Gooseneck are not provided
unless noted otherwise.)
© 2022, CyberData Corporation, ALL RIGHTS RESERVED
Need help?
Do you have a question about the 011214 and is the answer not in the manual?
Questions and answers