• Do not use the device with wet or damp hands. • Do not expose the device to directly squirting water. • Never insert any objects or limbs into the device. • Do not cover the device during operation. monobloc air conditioner without external unit PAC-W 2200 S...
Page 3
• Different types of batteries and new and used batteries • Observe the maximum refrigerant capacity in the technical must not be used together. data. • Do not drill through or burn. monobloc air conditioner without external unit PAC-W 2200 S...
Page 4
• have read and understood the operating manual, especially the Safety chapter. Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. monobloc air conditioner without external unit PAC-W 2200 S...
Page 5
P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking. P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P410+P403 – Protect from sunlight. Store in a well- ventilated place. monobloc air conditioner without external unit PAC-W 2200 S...
In addition, the device comes with a WiFi app control with additional functions. Designation Air inlet (with air filter) Air outlet with adjustable ventilation flap Control panel Wall mountings Air inlet Condensation drain Air outlet Remote control monobloc air conditioner without external unit PAC-W 2200 S...
• If required, use a cover to protect the device from invasive dust. • Place no further devices or objects on top of the device to prevent it from being damaged. • Remove batteries from the remote control. monobloc air conditioner without external unit PAC-W 2200 S...
Page 8
ð Observe the correct polarity. the exterior plaster is not damaged. 3. Slide the battery cover back onto the remote control. monobloc air conditioner without external unit PAC-W 2200 S...
Page 9
4. Use the template to mark the positions of the screws for 8. Roll the plastic film sheets into a tube and feed them the suspension rail. through the large wall holes until they are positioned flush with the interior wall. monobloc air conditioner without external unit PAC-W 2200 S...
Page 10
Prior to initial start-up, insert batteries in the remote control. Connecting the power cable • Insert the mains plug into a properly fused mains socket. monobloc air conditioner without external unit PAC-W 2200 S...
Dehumidification Illuminated when dehumidification mode is activated Night mode LED Illuminated when night mode is activated Fan speed LEDs Fan speed indication On / Off button Switching the device on or off monobloc air conditioner without external unit PAC-W 2200 S...
Page 12
• After 1 hour the preset temperature is increased by 1 °C. After another hour the preset temperature will again be increased by 1 °C. • Temperature and fan speed cannot be changed in night mode. monobloc air conditioner without external unit PAC-W 2200 S...
Page 13
Shutdown Warning of electrical voltage All settings can also be made via the Trotec Assistent App. The Do not touch the mains plug with wet or damp hands. settings of the timer functions that are operated via the app are •...
(in cooling mode). The compressor will not switch on unless the respective temperature is reached. • The compressor may start up with a delay of 3 minutes, as it is provided with an internal protection against direct restart. monobloc air conditioner without external unit PAC-W 2200 S...
Page 15
Software error of the mainboard Sensor on suction pipe error Water-splash motor error Sensor on discharge pipe error Fan feedback fault Temperature sensor error (outdoor) Water-full protection Fan motor error (outdoor) monobloc air conditioner without external unit PAC-W 2200 S...
Page 17
2. Clean the filter using a slightly damp, soft, lint-free cloth. If device cleaned by a specialist company for cooling and air- the filter is heavily contaminated, clean it with warm water conditioning or by Trotec. mixed with a neutral cleaning agent. monobloc air conditioner without external unit PAC-W 2200 S...
Minimum distance to walls and other objects: top: 20 cm sides: 10 cm front: 10 cm Weight 40.5 kg Remote control battery Type LR03 / AAA – 1.5 V Wifi frequency band 2.4 GHz monobloc air conditioner without external unit PAC-W 2200 S...
Page 19
Circuit diagram monobloc air conditioner without external unit PAC-W 2200 S...
Page 20
Overview and list of spare parts Note: The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. monobloc air conditioner without external unit PAC-W 2200 S...
Page 21
Support bar Condenser assembly WIFI protective box The after cover plate Transition tube Left base Back panel The compressor Plastic encapsulated motor Rear protection filter Compressor footing Filter Right trim strip Capillary monobloc air conditioner without external unit PAC-W 2200 S...
According to Waste Electrical and Electronic Equipment Regulations 2013 (2013/3113) and the Waste Batteries and Accumulators Regulations 2009 (2009/890), devices that are no longer usable must be collected separately and disposed of in an environmentally friendly manner. monobloc air conditioner without external unit PAC-W 2200 S...