Trotec PAC 2000 E Operating Manual

Trotec PAC 2000 E Operating Manual

Local air conditioner
Hide thumbs Also See for PAC 2000 E:

Advertisement

PAC 2000 E
EN
OPERATING MANUAL
LOCAL AIR CONDITIONER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAC 2000 E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trotec PAC 2000 E

  • Page 1 PAC 2000 E OPERATING MANUAL LOCAL AIR CONDITIONER...
  • Page 2: Table Of Contents

    Information marked with this symbol indicates that the operation. operating manual must be observed. • Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts. local air conditioner PAC 2000 E...
  • Page 3 • Any unauthorised modifications, such as alterations or structural changes to the device, are forbidden. • Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void. local air conditioner PAC 2000 E...
  • Page 4: Information About The Device

    Wheel used in all interior spaces. Air inlet with air filter Device depiction Air inlet Condensate outlet with rubber stopper Exhaust air hose connection Power cable holder Compartment for the remote control Remote control local air conditioner PAC 2000 E...
  • Page 5: Transport And Storage

    • Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service. • Set the device up in an upright and stable position. local air conditioner PAC 2000 E...
  • Page 6 • Make sure that the air filters are installed before switching the device on. 3. Attach the sealed condensation drain hose to the condensate outlet (6) and put the hose into the retaining clip. local air conditioner PAC 2000 E...
  • Page 7 • The end of the exhaust air hose can also be hooked into a tilted window. For this purpose, we recommend using a window seal (optional). • Install the exhaust air hose inclined with the air direction. Example with exhaust air hose: local air conditioner PAC 2000 E...
  • Page 8 • The dimensions of the exhaust air hose were especially made to fit the device. Do not replace or extend the hose, for it could cause a malfunction. local air conditioner PAC 2000 E...
  • Page 9: Operation

    Indication of target temperature indication temperature unit (degrees Celsius or Indication of error messages Fahrenheit) 15 Dehumidification Indication of the operating mode 35 Transmission Displayed during communication dehumidification indication between device and remote control local air conditioner PAC 2000 E...
  • Page 10 The function can be set in all operating modes and also during stand-by. The number of hours can be set in increments of 0.5 hours (0.5 h to 24 h). Note Do not leave the operating device unattended in a freely accessible room with an activated timer. local air conditioner PAC 2000 E...
  • Page 11 • Empty the condensation tray if necessary. • If necessary, remove the condensation drain hose and any residual fluid from it. • Clean the device according to the Maintenance chapter. • Store the device according to the Storage chapter. local air conditioner PAC 2000 E...
  • Page 12: Errors And Faults

    (in cooling mode). The compressor will not switch on unless the respective temperature is reached. • The compressor may start up with a delay of 3 min, as it is provided with an internal protection against direct restart. local air conditioner PAC 2000 E...
  • Page 13 Voltage at the mainboard is higher than the Contact Trotec ON/OFF overvoltage protection value button (17) The inside of the device is heavily contaminated Contact Trotec Overvoltage lights up briefly protection Remove any foreign objects and five times in a dirt from the air inlet and outlet.
  • Page 14 Error code Indication Fault Cause Remedy The inside of the device is heavily contaminated Contact Trotec Remove any foreign objects and dirt from the air inlet and outlet. Air inlet or air outlet is blocked Observe the minimum distances Refrigerant specified in the technical data n.
  • Page 15: Maintenance

    11. Date: ........12. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... 13. Date: ......... 14. Date: ........15. Date: ........16. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... local air conditioner PAC 2000 E...
  • Page 16 4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air- conditioning or by Trotec. 5. Put the air filter back in. local air conditioner PAC 2000 E...
  • Page 17 Ensure the tight fit of the rubber stopper, for otherwise there might be uncontrolled water leakage. 3. Remove the rubber stopper from the condensation drain hose. 6. Reattach the condensation drain hose to the retaining clip. local air conditioner PAC 2000 E...
  • Page 18: Technical Annex

    Minimum distance to walls and other objects: top (A): 30 cm rear (B): 30 cm sides (C): 30 cm front (D): 30 cm Weight 24 kg Remote control batteries Type LR03 / AAA – 1.5 V (2 pcs.) local air conditioner PAC 2000 E...
  • Page 19 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...