Table: 1.5
ENG
Special function
blocks
GER
Sondermodule
MODEL
DESCRIPTION
FX
-4DA
Digital to analog converter
2N
FX
-4AD
Analog to digital converter
2N
FX
-4AD-PT
PT100 probe interface
2N
FX
-4AD-TC
Thermo-couple interface
2N
FX
-1HC
High speed counter
2N
FX
-1PG
Pulse output, Position control -
2N
FX2N-232IF
RS232 Interface block
FX
-3A
Analog/Digital converter
0N
FX
-16NT
Net-mini interface
0N
FX
-32NT-DP
Profibus DP Interface
0N
Table: 1.6
ENG
FX Special function
blocks
GER
FX Sondermodule
MODEL
DESCRIPTION
FX-2DA
Digital to analog converter
FX-4DA
Digital to analog converter
FX-4AD
Analog to digital converter
FX-2AD-PT
PT100 probe interface
FX-4AD-TC
Thermo-couple interface
FX-1HC
High speed counter
FX-1PG-E
Pulse output, Position control -
FX-16NP/NT
Net-mini interface
FX-16NP/NT-S3 Net-mini-S3 interface
FX-1GM
Position Control (1 axis)
FX-10GM
Position Control (1 axis)
FX-20GM
Position Control (2 axis)
FX Special functions blocks must be connected at the right end of the system using
ENG
the FX
-CNV-IF convertion interface.
2N
Des blocs de fonctions spéciales FX doivent être connectés à l'extrémité droite du
FRE
système en utilisant l'interface de conversion FX
Die FX-Sondermodule müssen an der rechten Seite der Systemkonfiguration über die
GER
Schnittstelle FX
2N
I blocchi delle funzioni speciali FX devono essere collegati con l'estremità destra del
ITL
sistema usando l'interfaccia di conversione FX
El bloque funcional especial FX debe ser conectado al extremo derecho del sistema
ESP
a través de la interfase de conversión FX
NUMBER
POWER SUPPLY
OF I/O
Internal
I
O
5v DC
-
8
-
30 mA
-
8
-
30 mA
-
8
-
30 mA
-
8
-
30 mA
-
8
-
90 mA
8
-
55 mA
-
8
-
40 mA
-
8
-
30 mA
8
8
20 mA
-
8
-
170 mA
NUMBER
POWER SUPPLY
OF I/O
Internal
I
O
5v DC
-
8
-
30 mA
-
8
-
30 mA
-
8
-
30 mA
-
8
-
30 mA
-
8
-
40 mA
-
8
-
70 mA
8
-
60 mA
16
8
80 mA
8
8
8
80 mA
-
8
-
AC supply
-
8
-
-
-
8
-
AC supply
-CNV-IF angeschlossen werden.
-CNV-IF.
2N
Introduction
ESP
Módulos especiales
FRE
Modules spéciaux
ITL
Moduli speciali
DIMENSIONS
External
mm (inches)
24v DC
200 mA
55 mA
55 (2.1)
50 mA
90
87
(3.5)
(3.4)
50 mA
-
40 mA
43 (1.7)
80 mA
55 (2.1)
90 mA*
90
87
43 (1.7)
60 mA
(3.5)
(3.4)
20 mA
* Internal 24v DC
ESP
Módulos especiales
FRE
Modules spéciaux
ITL
Moduli speciali
DIMENSIONS
External
mm (inches)
24v DC
130 mA
200 mA
50 mA
73 (2.9)
50 mA
140
95
(5.5)
(3.7)
60 mA
-
40 mA
45 (1.8)
120 mA
100 mA 73 (2.9)
160
(6.3)
140
95
(5.5)
(3.7)
210 mA 50 (1.9)
110 (4.3)
-CNV-IF.
2N
-CNV-IF.
2N
1 - 7
1
WEIGHT
kg (lbs)
0.3 (0.66)
0.2 (0.44)
0.3 (0.66
0.2 (0.44)
0.3 (0.66)
WEIGHT
kg (lbs)
0.5 (1.1)
0.3 (0.66)
0.5 (1.1)
0.3 (0.66)
0.4 (0.88)
1.5 (3.3)
0.4 (0.88)

Advertisement