LiPo CutOff Volt
4.200V
LiHv CutOff Volt
4.350V
NiCd Sensitivity
D.Peak
Default
Temp
Cut-Off
ON
80C
176F
Waste Time
CHG>DCHG 5min
16、 User settings
Lipo cut o voltage range is 4.15-4.25V, we'd suggest user set
cut o voltage to 4.2V, to avoid exceed battery maximum
charging voltage causing damage to battery and your
property.
LiHv cut o voltage range is 4.30-4.4V, we'd suggest user set
cut o voltage to 4.35V, to avoid exceed battery maximum
charging voltage causing damage to battery and your
property.
The automatic charge trigger voltage, the working principle
is thatafter the battery voltage increased to the Maximum
value and startto decreasing, then the charge current will
turn o and nishthe charge. If the trigger voltage set higher,
there is a dangerofover- charging .If it is too low,there is a
possibility of stopcharging prematurely. Please refer to the
technicalspeci cation of the battery(NiCd default
voltage:12mv, NiMHdefault voltage:7mv).
There is a 3-pin socket on the left side of the charger, The
middle rowof pins is the temperature sensor interface. You
can select this function on the screen, then insert the
temperature sensor into the socket to monitor the
temperature of the battery. When detect the battery
temperature exceeds the set value, the charger will stop
charging / discharging to prevent battery overheat to
damage battery or causing more serious consequences.
Battery cycling charging/discharging waste time setting.
Battery temperature will rise when charging or
discharging.You can through set Battery cycling
charging/discharging waste time(can be 1-60 minutes) to let
battery have enough time to cooling down between each
cycling. You can set trickle charging mode to turn on/turn o .
When turn on trickle charging mode, the charger will
automatically provide a small charging current to achieve full
33