9.2 Discharging Pb battery
Pb
DICHG
3.4A
12.0V(6P)
4P
0.1A
7.76V
DSC 000:02 00000
9.3 Pb battery FB-DIS
FB-DIS can only be operated when the battery is connected to the input interface under DC
mode, otherwise will report error. The FB-DIS mode is to transfer the capacity of the battery
to be discharged to the input battery through the charger to achieve the purpose of
discharge. For your safety, the discharge current value displayed on the screen should not
exceed the maximum discharge current speci ed by the battery manufacturer, and the
rated voltage should not be lower than the voltage level recommended by the battery
manufacturer to avoid deep discharge. Select discharge battery type and voltage correctly.
Pb
DISCHG
2.0A
10.0V(5P)
SET INPUT BATT
Pb
14.7V(6P)
9.4 AGM battery charge program
Pb
AGM CHG
A
4.0V(2P)
Pb
0.4A
7.85V
CHG 000:04 00000
Set discharge current on the left side and nominal voltage on
the right. Press Start /Enter for 3 seconds to start the
discharging process. (current: 0.1~3.0A, battery voltage:
1-10P)
Set the discharge current value on the second line left side,
set the battery pack voltage on the right side. After set
nished, press and hold Start/Enter for 3 seconds to start the
program.(current: 0.1~12.0A,battery voltage: 1-10P)
Press ENTER to start program
Set input battery type and voltage, press and hold Start/Enter
for 3 seconds to start the program.
This charge program is specially designed for AGM battery.
The second line left side to set the charge current, the right
side is to set the battery pack voltage. After nished set, press
and hold Start/Enter for 3 seconds to start the program.
(current: 0.1~12.0A,battery voltage: 1-10P)