Pb Battery Program - G.T.Power C6D Pro Manual

Intelligent balance charger/dischager
Table of Contents

Advertisement

discharge. For your safety, the discharge current value displayed on the screen should not
exceed the maximum discharge current speci ed by the battery manufacturer, and the
rated voltage should not be lower than the voltage level recommended by the battery
manufacturer to avoid deep discharge. Select discharge battery type and voltage correctly.
NiMH
FB-DIS
12.0A
9.0V
SET INPUT BATT
Pb
14.7V(6P)
Lead Acid(PB)
Battery Mode
9.1 Charging Pb battery
Pb
CHARGE
3.4A
20.0V(10P)
Pb
0.7A
7.85V
CHG 000:04 00000
Set the charge current value on the second line left side, set
the battery pack voltage on the right side. After set nished,
press and hold Start/Enter for 3 seconds to start the
program.(current: 0.1~12.0A,battery voltage: 0.8-25V)
Press ENTER to start program
Set input battery type and voltage, press and hold Start/Enter
for 3 seconds to start the program.
9、 Pb battery program
This program is used for charging/discharging Pb batteries,
rated voltage from 2 to 20V.Pb batteries are di erent from
NIMH/NiCd batteries,Pb battery has a lower battery capacity
than NIMH/NiCd battery, they can only pass relatively lower
current,as well as have some current restraints during
charging process.Pb battery's current is 1/10 of its battery
capacity, it can't fast charging, you have to refer to the
speci cations of the battery manufacturer when charging.
Set charge current on the left side and nominal voltage on
the right. Press Start /Enter for 3 seconds to start the charging
process. (current: 0.1~12.0A, battery voltage: 1-10P)
26