QR5/QR5IP SERIES MANUAL
Function Code 05 - Call Forwarding
Enable or disable call. Default setting= 1 (enable). If 1 (disable) is selected, the system can't make calls
1.
Log-in to programming
2. Enter 05 then #
3. Enter 0= disable (default) pr 1= enable then press #
Function Code 06 - Add New Access Code
An access code is a keyless entry code to open the door. An access code can be programmed in 4, 5 ,6,7, or 8 digits, see
function code 09
to change the access code digit.
1.
Log-in to programming
2.
Enter 06 then #
3.
Enter the access code (4-8 digit, see
4.
Enter name up to 16 characters, then press #
5.
Enter door 1 or 2, or 3 for both, then press #
file:///C|/PACH-CO.COM-2022-B/online_manual/qr5_manual.htm[4/25/2022 2:58:06 PM]
function code 09
), then press #
see
Chapter 3
for keypad layout