QR5/QR5IP SERIES MANUAL QUANTUM QR5/QR5IP SERIES PROGRAMMING MANUAL V04122022 TABLE OF CONTENTS Table of Contents Limitation of Liability Function Code 23: Lock-out Count Function Code 24: Alarm Products Limited Warranty Function Code 25: Keypad Beep Function Code26: Door Beep Limited Warranty Limits and Exclusions Function Code 27: Talk Time Function Code 28: Unlock Relay 1 Time CHAPTER 1 GETTING STARTED...
QR5/QR5IP SERIES MANUAL Function 50: Erase Memory to Factory Default Function Code 10: Add Card Function Code 51: Welcome Screen Function Code 11: Delete Card Function Code 12: Clear All Cards CHAPTER 5 OPERATIONS Function Code 13: Set Time Function Code 14: Set Date Call from the System Function Code 15: Initializing Event Recording Opening Door Remotely...
QR5/QR5IP SERIES MANUAL This limited warranty ONLY COVERS failures due to defects in materials or workmanship, and DOES NOT COVER normal wear and tear or cosmetic damage. The Limited Warranty ALSO DOES NOT COVER damages which occurred in shipment, or failures which result from accidents, misuse, abuse, neglect, bug infestation, mishandling, misapplication, alteration, faulty installation, setup adjustment, misadjustment of consumer controls, improper maintenance, power line surge, lightning damage, modification, introduction to sand, humidity or liquids or product has been installed by non-license installer or damage that is...
QR5/QR5IP SERIES MANUAL Capacity 10 tenants, 100 cards and 100 access codes. Specification Input power: 12VAC 40VA (12VAC supplied) or 12VDC 3.0A Minimal Current consumption: 750-100mA DIMENSION: 9-13/16"(H) x 11-13/16"(W) x 3-1/2"(D) 1x16 Liquid Crystal Display (LCD) Built-in 26 Bit Wiegand Card Reader RS-485 for Satellite system (up to eight satellite) Two on-board relays Two Auxiliary inputs...
Page 5
QR5/QR5IP SERIES MANUAL 1. AC1 and AC2, Input Power 12VAC 40VA (supplied) or 12VDC 3.0A (not supplied). Measurement voltage under load must be 12.50-14.00 VAC (AC Transformer) or 13.50-14.00 VDC (DC power supply) 2. BAT and GND, Battery backup 12VDC 4.5Ahr. 3.
QR5/QR5IP SERIES MANUAL CHAPTER 3 Keypad Correlation Table The QR5 buttons are lighted. Below are the correlation table for each key. = 1 _ . , ? : ; ! @ + - * / = # < > % M N O m n o 6 A B C a b c 2 P Q R S p q r s 7...
QR5/QR5IP SERIES MANUAL 3. Enter new master code then press # Function code 01 - Add New Tenant Directory A tenant directory consists of directory code (2, 3 or 4 digits depending on the setup, see fucntion code 19), tenant's name and phone number.
QR5/QR5IP SERIES MANUAL Enter new name up to 16 characters then press # or press # keep the existing name Chapter 3 for keypad layout Enter the a new tenant phone number up to 16-digit then press # or press # to keep the existing phone number. Return to step 3 to edit another tenant directory Function Code 03 - Delete Tenant Directory Log-in to programming...
QR5/QR5IP SERIES MANUAL Function Code 05 - Call Forwarding Enable or disable call. Default setting= 1 (enable). If 1 (disable) is selected, the system can't make calls Log-in to programming 2. Enter 05 then # 3. Enter 0= disable (default) pr 1= enable then press # Function Code 06 - Add New Access Code An access code is a keyless entry code to open the door.
QR5/QR5IP SERIES MANUAL Enter time zone 1-3 then press # Enter 00 (24 hours) - 20 see function code 17 then press # Enter satellite system ID 0-7 (enter 0 if no satellite system connected to the main system) then press # Enter 0= no more additional time zone then press # and return to step 3...
QR5/QR5IP SERIES MANUAL Enter 1 to clear all access code then press # * to cancel Function Code 09 - Access Code Digit Log-in to programming Enter 09 then #| 3. Enter 4, 5, 6, 7 or 8 (default setting is 4 digit) then press # Function Code 10 - Add C Log-in to programming Enter 10 then #...
Page 12
QR5/QR5IP SERIES MANUAL Enter door 1 or 2, or 3 for both then press # Enter time zone 1-3 then press # Enter 00 (24 hours) - 20 see function code 17 then press # Enter satellite system ID 0-7 (enter 0 if no satellite connected to the main system) then press # Enter 0= no more additional time zone then press # and return to step 3...
Page 13
QR5/QR5IP SERIES MANUAL Log-in to programming Enter 12 then # Enter 1 to clear all keyfobs or cards press # or * to cancel Function Code 13 - Set Time Log-in to programming Enter 13 then # Enter HH= in military time MM= minute the press # Function Code 14 - Set Date...
Page 14
QR5/QR5IP SERIES MANUAL 0= Sunday, 1= Monday, 2= Tuesday, 3= Wednesday, 4= Thursday, 5= Friday, 6= Saturday then press # 5. Enter 0= NO Daylight Saving Zone (Hawaii, Indiana and Arizona) 1=Daylight Saving Zone then press # Function Code 15 - Initializing Event recording The events are stored in the RAM buffer.
Page 15
QR5/QR5IP SERIES MANUAL 1= Add AUS then press # Enter open time in military then press # Enter close time in military then press # Enter 0= Sunday, 1= Monday, 2= Tuesday, 3= Wednesday, 4= Thursday, 5= Friday, 6= Saturday then press # 8.
Page 16
QR5/QR5IP SERIES MANUAL 1= add new time zone then press # Enter start time in military then press # Enter end time in military then press # Enter 0= Sunday, 1= Monday, 2= Tuesday, 3= Wednesday, 4= Thursday, 5= Friday, 6= Saturday then press # Return to step 3 to program more time zone Function Code 18 - Holiday Zone (HLD)
Page 17
QR5/QR5IP SERIES MANUAL 5. Enter month and date (i.e. 0704 for U.S.A Independence Day) then press # Return to step 3 to add more holiday zones. Function Code 19 - Directory Digit Directory digit is a unique number that must be assigned for each tenant. By default, the directory is set to 2 digit but can be changed to 3 or 4 digits.
QR5/QR5IP SERIES MANUAL Enter 21 then # 3. Enter 0= disable (default setting) 1= Enable control by relay 2 open door interval, see function code 29 2= relay 2 control by AUXIN2 then press # Function Code 22 - Do Not Disturb If Do Not Disturb is enabled, then the calling feature is disabled.
QR5/QR5IP SERIES MANUAL Log-in to programming 2. Enter 24 then # 3. Enter 0= disable, 1=disable system for 60 seconds and local beep (default setting), 2= disable system for 60 seconds with no beep 3= call directory (0-9) then press # Function Code 25 Keypad Beep Turn the keypad press beep On or Off Log-in to programming...
QR5/QR5IP SERIES MANUAL 3. Enter 10-240 seconds then press # Function Code 28 Unlock Relay 1 Time The amount of time for relay 1 to trigger. Log-in to programming Enter 28 then # 3. Enter 01-99 (second) then press # Function Code 29 Unlock Relay 2 Time The amount of time for relay 2 to trigger.
QR5/QR5IP SERIES MANUAL Function Code 31 Call Forwarding Time Intercom call can be forwarded to an outside line (land line, cellular phone) between 15-60 seconds. The call forwarding time must be set shorter than your voice mail or answering machine answers time otherwise it will not work. Automatic call forwarding will work if the system calls outside line.
QR5/QR5IP SERIES MANUAL 4. Enter code number 01-10 then press # Enter 4-8 digit code, see digit setting on function code 09 Chapter 3 for keypad layout 6. Enter name then press # 7. Enter 1= relay 1(door 1), 2= relay 2 (door 2) or 3= both relay then press # 8.
Page 23
QR5/QR5IP SERIES MANUAL codes can be programmed. Log-in to programming 2. Enter 34 then # 3. Enter 0= delete 1= add then press # 4. Enter code 01-10 then press # 5. Enter 4-8 digit code, see digit setting on function code 09 Chapter 3 for keypad layout...
QR5/QR5IP SERIES MANUAL 1= add additional time zone then press # and return to step 8 * = exit programming Function Code 35 Temporary Card The card will be expired after being used a certain amount of times specified (1-10 times) in the programming, Up to 10 temporary cards can be programmed.
QR5/QR5IP SERIES MANUAL 10. Enter Sat ID 0-7 then press # (enter 0 if no satellite connected to the QR5) 11. Enter 0= no more additional time zone then press # and return to step 3 to program another temporary code 1= add additional time zone then press # and return to step 8 * = exit programming...
QR5/QR5IP SERIES MANUAL 7. Enter 1= relay 1(door 1), 2= relay 2 (door 2) or 3= both relay then press # 8. Enter time zone 1-3 then press # 9. Enter 00 (24 hours) - 20 see function code 17 then press # 10.
QR5/QR5IP SERIES MANUAL 2. Enter 39 then # 3. Press 0= disable remote access 1= enable remote access (default) then press # Function Code 40 DTMF Relay 1 By default the DTMF remote opening relay 1 (door 1) key number is set to 9 means pressing 9 will remotely trigger relay 1 (door 1).
QR5/QR5IP SERIES MANUAL Log-in to programming 2. Enter 42 then # 3. Enter 1= door control, 2=trigger simultaneously as relay 1, 3= alarm mode (see function code 24), 4= turn relay 2 on/off remotely (DTMF key 7/6), then press # Function Code 43 Do Not Disturb Time Zone If you do not want to be disturbed from someone calling you from the system during certain hours of the days, you can create Do Not Disturb Time Zone.
QR5/QR5IP SERIES MANUAL Function Code 44 Disable Time Zone Relay The system's relay can be disabled during certain time but the system is still in full operation. Maximum 10 disable time zones. Log-in to programming 2. Enter 44 then # 3.
QR5/QR5IP SERIES MANUAL Relay 1 and 2 can be unlock using count down timer 01-98 hours or 00=lock or 99= unlimited unlock hold. Log-in to programming 2. Enter 45 then # 3. Enter relay 1 (door 1) then press # then press # or relay 2 (door 2) then press #, then press #...
QR5/QR5IP SERIES MANUAL 4. Enter the number to access dial tone to dial an outside line, generally 9 is the default number for most PBX system, then press # 5. Select delay time for the PBX system to access dial tone, generally 2-3 second delay is plenty of time, then press # Function Code 49 Edit Existing Access Code, Temporary Code and Special Code Log-in to programming 2.
Page 32
QR5/QR5IP SERIES MANUAL It consists of three segments and 16 characters for each segment Log-in to programming 2. Enter 51 then # 3. 1st segment, enter the characters then press # see Chapter 3 for keypad layout 4. 2nd segment, enter the characters then press # see Chapter 3 for keypad layout CHAPTER 5...
Page 33
QR5/QR5IP SERIES MANUAL The Quantum QR5 or QR5IP Series has built-in card reader. The door can be access using UFOB, UCLAM or UISO. Card Standard Operation is used to open the door and door will be closed automatically, see function code 10 Temporary Card is used for limited of times, maximum 10 times then the card will be expired, see function code 35 Special Card is used to unlock hold door and then use same card to lock the door, see...
Page 34
QR5/QR5IP SERIES MANUAL The QWCM Web Based module is included on QR5 or QR5IP Series. Click here for QWCM manual DEFAULT SETTING QWCM IP: 192.168.1.230 SUBNET: 255.255.255.0 GATEWAY: 192.168.1.1 DNS: 192.168.1.1 USERNAME: Administrator PASSWORD: pach or 8888 file:///C|/PACH-CO.COM-2022-B/online_manual/qr5_manual.htm[4/25/2022 2:58:06 PM]...