QC SERIES MANUAL QUANTUM QC SERIES PROGRAMMING MANUAL V04122022 TABLE OF CONTENTS Table of Contents Limitation of Liability Function Code 23: Lock-out Count Function Code 24: Alarm Products Limited Warranty Function Code 25: Keypad Beep Function Code26: Door Beep Limited Warranty Limits and Exclusions...
Pach and Company does not assume any liability for any damages, which may arise in installation or use of the Quantum QC Series Pach and Company does not assume liability for any incompatibility between the Quantum QC Series and users devices.
Pach & Company thanks and congratulates you on the purchase of your Quantum QC Series Telephone Entry Access Control Systems. The manual is designed to guide you through the proper programming and use of the Quantum QC Series It is important for you to read and follow the manual completely.
QC SERIES MANUAL RS-485 for Satellite system (up to eight satellite) Two on-board relays Two Auxiliary inputs Operating environment 10ºF-140ºF Relative Humidity 0%-95% non-condensing Double 3/4" knocks-out on the back and bottom panel Features Web Based programming Event recording Automatic Enrollment 100-600 tenants, 300-3000 cards, 300-3000 access codes, depending on the model number 20 programmable time zones, 10 programmable auto-unlock schedules and 20 holiday schedules 10 programmable temporary cards and access codes for limited use...
Page 5
QC SERIES MANUAL 1. AC1 and AC2, Input Power 12VAC 40VA (supplied) or 12VDC 3.0A (not supplied). Measurement voltage under load must be 12.50-14.00 VAC (AC Transformer) or 13.50-14.00 VDC (DC power supply) 2. BAT and GND, Battery backup 12VDC 4.5Ahr. 3.
QC SERIES MANUAL LCD Display OK --- Flash OK --- RTC OK --- DTMF OK --- INIT START --- INIT COMPLTE --- SCROLLING CHAPTER 3 Keypad Correlation Table The QR5 buttons are lighted. Below are the correlation table for each key. = 1 _ .
QC SERIES MANUAL Enter 00 then # 3. Enter new master code then press # Function code 01 - Add New Tenant Directory A tenant directory consists of directory code (2, 3 or 4 digits depending on the setup, see fucntion code 19), tenant's name and phone number.
QC SERIES MANUAL Enter tenant directory number to be edited then # Enter new name up to 16 characters then press # or press # keep the existing name Chapter 3 for keypad layout Enter the a new tenant phone number up to 16-digit then press # or press # to keep the existing phone number. Return to step 3 to edit another tenant directory Function Code 03 - Delete Tenant Directory Log-in to programming...
QC SERIES MANUAL - Press 1 (to clear all directories) then press # - Press * to cancel Function Code 05 - Call Forwarding Enable or disable call. Default setting= 1 (enable). If 1 (disable) is selected, the system can't make calls Log-in to programming 2.
QC SERIES MANUAL Enter time zone 1-3 then press # Enter 00 (24 hours) - 20 see function code 17 then press # Enter satellite system ID 0-7 (enter 0 if no satellite system connected to the main system) then press # Enter 0= no more additional time zone then press # and return to step 3...
QC SERIES MANUAL Enter 07 then # Enter 1 to clear all access code then press # * to cancel Function Code 09 - Access Code Digit Log-in to programming Enter 09 then #| 3. Enter 4, 5, 6, 7 or 8 (default setting is 4 digit) then press # Function Code 10 - Add C Log-in to programming Enter 10 then #...
Page 12
QC SERIES MANUAL Enter door 1 or 2, or 3 for both then press # Enter time zone 1-3 then press # Enter 00 (24 hours) - 20 see function code 17 then press # Enter satellite system ID 0-7 (enter 0 if no satellite connected to the main system) then press # Enter 0= no more additional time zone then press # and return to step 3...
Page 13
QC SERIES MANUAL Log-in to programming Enter 12 then # Enter 1 to clear all keyfobs or cards press # or * to cancel Function Code 13 - Set Time Log-in to programming Enter 13 then # Enter HH= in military time MM= minute the press # Function Code 14 - Set Date...
Page 14
QC SERIES MANUAL Enter 0= Sunday, 1= Monday, 2= Tuesday, 3= Wednesday, 4= Thursday, 5= Friday, 6= Saturday then press # 5. Enter 0= NO Daylight Saving Zone (Hawaii, Indiana and Arizona) 1=Daylight Saving Zone then press # Function Code 15 - Initializing Event recording The events are stored in the RAM buffer.
Page 15
QC SERIES MANUAL 0= Delete the existing AUS the press # 1= Add AUS then press # Enter open time in military then press # Enter close time in military then press # Enter 0= Sunday, 1= Monday, 2= Tuesday, 3= Wednesday, 4= Thursday, 5= Friday, 6= Saturday then press # 8.
Page 16
QC SERIES MANUAL 0= Delete the existing time zone then press # 1= add new time zone then press # Enter start time in military then press # Enter end time in military then press # Enter 0= Sunday, 1= Monday, 2= Tuesday, 3= Wednesday, 4= Thursday, 5= Friday, 6= Saturday then press # Return to step 3 to program more time zone Function Code 18 - Holiday Zone (HLD)
Page 17
QC SERIES MANUAL 1= add new holiday zone then press # 5. Enter month and date (i.e. 0704 for U.S.A Independence Day) then press # Return to step 3 to add more holiday zones. Function Code 19 - Directory Digit Directory digit is a unique number that must be assigned for each tenant.
QC SERIES MANUAL Log-in to programming Enter 21 then # 3. Enter 0= disable (default setting) 1= Enable control by relay 2 open door interval, see function code 29 2= relay 2 control by AUXIN2 then press # Function Code 22 - Do Not Disturb If Do Not Disturb is enabled, then the calling feature is disabled.
QC SERIES MANUAL The system has a warning alarm if invalid code or card has been enter according to the setting on function code 23. Log-in to programming 2. Enter 24 then # 3. Enter 0= disable, 1=disable system for 60 seconds and local beep (default setting), 2= disable system for 60 seconds with no beep 3= call directory (0-9) then press # Function Code 25 Keypad Beep...
QC SERIES MANUAL 2. Enter 27 then # 3. Enter 10-240 seconds then press # Function Code 28 Unlock Relay 1 Time The amount of time for relay 1 to trigger. Log-in to programming Enter 28 then # 3. Enter 01-99 (second) then press # Function Code 29 Unlock Relay 2 Time The amount of time for relay 2 to trigger.
Page 21
QC SERIES MANUAL 3. Enter 0= delete existing temporary code or 1= add temporary code then press # 4. Enter code number 01-10 then press # Enter 4-8 digit code, see digit setting on function code 09 Chapter 3 for keypad layout 6.
QC SERIES MANUAL Function Code 34 Special Code The code can be use to unlock hold (open hold) and use same code again to lock (close) door or gate. Up to 10 special codes can be programmed. Log-in to programming 2.
QC SERIES MANUAL 11. Enter 0= no more additional time zone then press # and return to step 3 to program another temporary code 1= add additional time zone then press # and return to step 8 * = exit programming Function Code 35 Temporary Card The card will be expired after being used a certain amount of times specified (1-10 times) in the programming, Up to 10 temporary cards can be programmed.
QC SERIES MANUAL 9. Enter 00 (24 hours) - 20 see function code 17 then press # 10. Enter Sat ID 0-7 then press # (enter 0 if no satellite connected to the QR5) 11. Enter 0= no more additional time zone then press # and return to step 3 to program another temporary code 1= add additional time zone then press # and return to...
QC SERIES MANUAL then press # 7. Enter 1= relay 1(door 1), 2= relay 2 (door 2) or 3= both relay then press # 8. Enter time zone 1-3 then press # 9. Enter 00 (24 hours) - 20 see function code 17 then press # 10.
QC SERIES MANUAL If no remote opening allow, disable it using this function code. Default setting is enabled. Log-in to programming 2. Enter 39 then # 3. Press 0= disable remote access 1= enable remote access (default) then press # Function Code 40 DTMF Relay 1 By default the DTMF remote opening relay 1 (door 1) key number is set to 9 means pressing 9 will remotely trigger relay 1 (door 1).
QC SERIES MANUAL Function Code 42 Relay 2 Mode Relay 2 can be set to four different mode: 1= door control, 2= trigger simultaneously as relay 1, 3= alarm mode (see function code 24), 4= turn relay 2 on/off remotely (DTMF key7/6) Log-in to programming 2.
QC SERIES MANUAL 0= Sunday, 1= Monday, 2= Tuesday, 3= Wednesday, 4= Thursday, 5= Friday, 6= Saturday then press # Return to step 3 to program another time zone Function Code 44 Disable Time Zone Relay The system's relay can be disabled during certain time but the system is still in full operation. Maximum 10 disable time zones.
QC SERIES MANUAL Function Code 45 Relay 1 and 2 Unlock Timer Relay 1 and 2 can be unlock using count down timer 01-98 hours or 00=lock or 99= unlimited unlock hold. Log-in to programming 2. Enter 45 then # 3.
QC SERIES MANUAL 3. Enter 0= disable or 1= enable then press # 4. Enter the number to access dial tone to dial an outside line, generally 9 is the default number for most PBX system, then press # 5. Select delay time for the PBX system to access dial tone, generally 2-3 second delay is plenty of time, then press # Function Code 49 Edit Existing Access Code, Temporary Code and Special Code Log-in to programming 2.
QC SERIES MANUAL Function Code 51 Welcome Screen It consists of three segments and 16 characters for each segment Log-in to programming 2. Enter 51 then # 3. 1st segment, enter the characters then press # see Chapter 3 for keypad layout 4.
Page 32
5.4 Opening Door Using Card, Temporary Card, and Special Card The Quantum QC Series has built-in card reader. The door can be access using UFOB, UCLAM or UISO. Card Standard Operation is used to open the door and door will be closed automatically, see...
Page 33
QC SERIES MANUAL CHAPTER 6 QWCM Internet IP Module The QWCM Web Based module is included for all IP and VOIP Series. Click here for QWCM manual QWCM DEFAULT SETTING IP: 192.168.1.230 SUBNET: 255.255.255.0 GATEWAY: 192.168.1.1 DNS: 192.168.1.1 USERNAME: Administrator PASSWORD: pach or 8888 file:///C|/PACH-CO.COM-2022-B/online_manual/qc_series_manual.htm[4/27/2022 8:58:09 AM]...