ADTRAN Total Reach DDS-DP 5 Series Installation And Maintenance Manual
ADTRAN Total Reach DDS-DP 5 Series Installation And Maintenance Manual

ADTRAN Total Reach DDS-DP 5 Series Installation And Maintenance Manual

Total reach all-rate dds dataport
Hide thumbs Also See for Total Reach DDS-DP 5 Series:

Advertisement

Quick Links

CONTENTS
1.
GENERAL.......................................................... 1
2.
OPTIONS ........................................................... 2
3.
INSTALLATION ............................................... 3
4.
TESTING ............................................................ 4
5.
DEPLOYMENT GUIDELINES ........................ 5
6.
MAINTENANCE ............................................... 6
7.
FIGURES
Figure 3. Option Switch .......................................... 2
LBK Button .............................................. 5
TABLES
Option Settings ......................................... 2
Compliance Codes ................................... 3
LED Indication ......................................... 4
Data@13.3 kHz ........................................ 5

1. GENERAL

This practice provides installation and maintenance
procedures for the ADTRAN Series 5 Total Reach
DDS-DP All-Rate DDS Dataport. Figure 1 is an
illustration of the ADTRAN Series 5 Total Reach
DDS-DP, P/N 1433105L1.
Revision History
This document has been revised to incorporate the
response to the loopback pushbutton function of the
DDS-R ACE remote unit, and add reference to false
latching loopback prevention at 64 kbps.
Description
The ADTRAN Series 5 Total Reach DDS-DP is a
functional replacement for the SLC
DP, CLEI 5SCU48, delivering data at rates up to 64
kbps using a single copper pair. Used in combination
with the DDS-R termination unit, the Series 5
61433105L1-5F
Series 5 Total Reach
Total Reach All-Rate DDS Dataport
Installation and Maintenance
®
Series 5 OCU
Section 61433105L1, Issue 6
Trademarks: Any brand names and product names included in this document are trademarks,
registered trademarks, or trade names of their respective holders.
®
DDS-DP
SW2

Figure 1. Series 5 Total Reach DDS-DP

DDS-DP can accommodate extended loop lengths,
eliminating the need for DDS repeaters. The Series 5
DDS-DP span powers the DDS-R located at the
customer premises. The DDS-R converts the 2-wire
signal to the traditional 4-wire Alternate Mark
Inversion (AMI) signal for presentation to the
customer.
The DDS-DP occupies a single channel position in the
AT&T
®
SLC Series 5 or Series 5 compatible channel
bank. It provides the interface between a DS0 time
slot of the T-carrier data stream and the 2-wire
metallic loop extending to the customer premises. The
Series 5 Total Reach DDS-DP will interoperate over
the carrier system with another DDS-DP, OCU DP,
DS0 DP, 1/0 DCS, or switch and can be located in an
end office, hub office, intermediate office, or Digital
Loop Carrier (Figure 2). The 2-wire loop is
connected using the odd pair Tip (pin 31) and Ring
(pin 32) on the Series 5 backplane.
NOTE
The Series 5 Total Reach DDS-DP must be used
with an appropriate DDS-R unit.
Section 61433105L1-5F
Issue 6, June 2002
CLEI Code: 5SC53X4F_ _
DDS -DP
14331 05
SX
SYN C
FE
NE
QM
DSU
LBK
MAN
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Total Reach DDS-DP 5 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ADTRAN Total Reach DDS-DP 5 Series

  • Page 1: Table Of Contents

    64 kbps. connected using the odd pair Tip (pin 31) and Ring Description (pin 32) on the Series 5 backplane. The ADTRAN Series 5 Total Reach DDS-DP is a ® functional replacement for the SLC Series 5 OCU...
  • Page 2: Options

    Table 1. Option Settings SERIES 5 Customer Premises 4-Wire Customer Interface 2-Wire Loop T-Carrier DDS-R DDS-DP DSU/CSU T/R Pair , 6 . i t c , 2 . : t c Figure 2. Total Reach DDS Circuit Diagram Features l i a : t c •...
  • Page 3: Installation

    When SW56 (SW2-3) is ON, the DDS-DP enables After unpacking the unit, inspect it for damage. If Switched-56 operation. damage is discovered, file a claim with the carrier, then contact ADTRAN. Refer to Warranty and Customer Service. NOTE Only one rate should be selected. Service rates Compliance of 64 kbps, 19.2 kbps, and Switched-56 are not...
  • Page 4: Testing

    Span Power 4. TESTING Span powering is accomplished using -130 VDC Testing for the DDS-DP is accomplished using the measured from Tip to Ring. Voltage measured from same test procedures for 4-wire OCU and OCU DP Tip to GND should be -130 VDC or less depending on units.
  • Page 5: Deployment Guidelines

    Loopback Pushbutton (Remote Unit) NOTE The DDS-DP initiates a loopback in response to a The 50 dB AML limit includes 6 dB of signal remote unit with a loopback pushbutton feature, margin to account for potential near-end cross Figure 6. This allows a field technician or craft talk (NEXT) from other digital services that personnel to conduct loop testing from the remote end may be provisioned in the same binder group.
  • Page 6: Maintenance

    ADTRAN Technical Support 7. WARRANTY AND CUSTOMER SERVICE Pre-sales Applications/Post-sales Technical Assistance ADTRAN will replace or repair this product within (800) 726-8663 ten (10) years from the date of shipment if it does not meet its published specifications or fails while in Standard hours: Monday-Friday, 7 a.m.

Table of Contents