Total Access 1500
Total Reach DDS-DP
Installation and Maintenance Guide
Document Number: 61180105L1-5C
CLEI: VAL2JG0A_ _
July 2010

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN Total Access 1500 Total Reach DDS-DP

  • Page 1 Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Document Number: 61180105L1-5C CLEI: VAL2JG0A_ _ July 2010...
  • Page 2 Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Front Matter Trademarks Brand names and product names included in this document are trademarks, registered trade‐ marks, or trade names of their respective holders. To the Holder of this Document ® The contents of this document are current as of the date of publication. ADTRAN  reserves  the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequential damages or  for commercial losses even if ADTRAN has been advised thereof as a result of issue of this  document. About this Document This document provides instructions for the installation and maintenance of the Total Reach  DDS‐DP. The intended audience for this information is the craftperson responsible for the  installation and maintenance of the equipment. These instructions assume familiarity with the  intended use of the equipment, basic required installation skills, and knowledge of local and  accepted safety practices. Additionally, this document provides provisioning information specific to the User Interface  of the Total Reach DDS‐DP. The intended audience for this information is system  management personnel responsible for the configuration of the software applications. User  Interface provisioning assumes familiarity with the intended use of the equipment, concepts ...
  • Page 3 Revision History Revision History Revision Date Description October 2001  Initial release.  September 2002 Clarifies testing and installation, and adds option menu screens. June 2010 Correct dip switch function. Conventions The following typographical conventions are used in this document: This font indicates a cross‐reference link.  This font  indicates screen menus, fields, and parameters.  indicates keyboard keys ( E ,  E ,  A ). Keys that are to be pressed simultaneously  HIS FONT NTER are shown with a plus sign ( A indicates that the  A key and  key should be pressed at the  same time ). This font indicates references to other documentation and is also used for emphasis. This font  indicates on‐screen messages and prompts.
  • Page 4 Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Hazard Classifications The following hazard classifications are used in this document: DANGER DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. CAUTION can also be used to alert against unsafe practices associated with events that could lead to personal injury. NOTICE Notice call‐outs indicate a potentially hazardous situation not related to personal injury, such as messages related to property damage only. NOTE Notes inform the user of additional, but essential, information or features. Metric Conversion The Total Access 1500 is designed to fit standard 19‐inch and 23‐inch racks, occupying 2U of  vertical space. 1U equals 1 rack unit of vertical height, which equals 1.75 inches or 44.5 milli‐ meters. The following metric conversions apply: • Height:  3.125 inches = 79.375 millimeters • Width:  0.62 inches = 15.748 millimeters • 2U (3.5 inches) = 89 millimeters...
  • Page 5 How to Navigate this Document How to Navigate this Document Menus found at the same level in the User Interface appear at the same heading level in this  document, with the sub‐menus arranged to follow sequentially at lower heading levels. To assist in navigation, a Path Heading appears below each topic heading in these sections,  displaying the menu path to that feature. For example: Product Name Installation and Maintenance Guide Network Management Main Menu\System Controller\Provisioning\Network Management\ Top Level Two Levels One Level Current Above Current Above Current Menu/Screen NOTE When viewing this document in PDF form, the headings shown in blue are links to the higher menu levels.
  • Page 6 Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Icons The following icons are used throughout the ADTRAN document suite: jobAid installation guide deployment guide application guide reference guide diagnostic guide safety and regulatory engineering guide release notes upgrade guide user guide Training ADTRAN offers training courses on our products. These courses include overviews on  product features and functions while covering applications of ADTRAN product lines.  ADTRAN provides a variety of training options, including customized training and courses  taught at our facilities or at customer sites. For inquiries concerning training, contact ADTRAN: Training Phone: 800‐615‐1176, ext. 6303...
  • Page 7: Table Of Contents

    Contents Scope of this Guide ..........1 Related Documentation .
  • Page 8 ADTRAN Technical Support ........
  • Page 9 Figures Figures Figure 1. Total Reach DDS-DP Circuit Diagram ....... . 3 Figure 2.
  • Page 10 Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Tables Table 1. Topic List ............1 Table 2.
  • Page 11: Scope Of This Guide

    Total Access 1500 Total Reach DDS-DP Scope of this Guide This document provides instructions for the installation and maintenance of the Total Access  1500 Total Reach DDS‐DP.  Furthermore, this guide provides provisioning defaults, User Interface fundamentals, and  descriptions of the Total Access 1500 Total Reach DDS‐DP menus. This guide contains the topics listed in Table 1. Table 1. Topic List Topic See Page Introduction Safety and Regulatory Compliance Installation Provisioning General Keyboard Commands Main Menu Maintenance Specifications 61180105L1-5C...
  • Page 12: Related Documentation

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Related Documentation Refer to Table 2 for additional, detailed information concerning the Total Access 1500 Total  Reach DDS‐DP. Table 2. Related Documentation Title Part Number Total Access 1500 Component‐level Documentation Total Access 1500 Total Reach DDS‐DP Job Aid  61180105L1‐22 Total Access 1500 System‐level Documentation Total Access 1500 System Manual 61180105L1‐1 61180105L1-5C...
  • Page 13: Introduction

    Introduction Introduction This practice provides installation and maintenance procedures for the ADTRAN Total Access  1500 Total Reach DDS‐DP (TR DDS‐DP). The figure on the left, illustrates the front panel of the  TR DDS‐DP (P/N 61180105L1). Description The TR DDS‐DP delivers data at rates up to 64 kbps using a single copper pair. Used in combi‐ nation with the Total Reach DDS‐R termination unit, the Total Reach DDS‐DP can accom‐ modate extended loop lengths, eliminating the need for DDS repeaters.  • The TR DDS‐DP span powers the remote DDS‐R located at the customer premises.  • The DDS‐R converts the 2‐wire signal to the traditional 4‐wire Alternate Mark Inversion  (AMI) signal for presentation to the customer. The TR DDS‐DP occupies a single channel position in the Total Access 1500 chassis. It  provides the interface between a DS0 time slot of the T‐carrier data stream and the 2‐wire  metallic loop extending to the customer premises. The TR DDS‐DP will interoperate over the  carrier system with another TR DDS‐DP, OCU DP, DS0 DP, 1/0 DCS, or switch and can be  located in an end office, hub office, intermediate office, or Digital Loop Carrier (see Figure 1).  The 2‐wire loop is connected using the Tip (pin 15) and the Ring (pin 35) on the Total Access  1500 backplane. Total Access 1500 DDS- Figure 1. Total Reach DDS-DP Circuit Diagram Features • All standard rates to 56 kbps with or without secondary channel • 64 kbps clear channel • 2‐wire deployment • Repeaterless operation •...
  • Page 14: Safety And Regulatory Compliance

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide • Protected loopback eliminates false latching loopback occurrences • Supports DDS latching loopback standard T1E1.2/99‐007R1 Safety and Regulatory Compliance CAUTION C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY.
  • Page 15: Installation

    Installation Installation After unpacking the unit, inspect it for damage. If damage is discovered, file a claim with the  carrier, then contact ADTRAN. Refer to Warranty and Customer Service. Shipping Contents The contents include the following items: • Total Reach DDS‐DP • Total Access 1500 Total Reach DDS‐DP Job Aid (P/N 61180105L1‐22) Instructions for Installing the Module The TR DDS‐DP plugs directly into a Total Access 1500 shelf. No special wiring is required.  The 2‐wire loop uses the T/R (Tip and Ring) pair, pins 15 and 35, of the Total Access 1500  backplane. Remote Unit Span Power The TR DDS‐DP span powers the remote unit by providing ‐130 VDC measured from Tip to  Ring. Voltage measured from Tip to GND should be ‐130 VDC or less depending on voltmeter  impedance. Voltage from Ring to GND should indicate approximately 0 V. Front Panel LEDs The TR DDS‐DP provides front panel LEDs to display status information. The TR DDS‐DP  LEDs and status descriptions are shown in Table 4. Table 4. Front Panel LEDs Condition Description STATUS No power or malfunction Green Normal synchronized operating condition...
  • Page 16: Synchronization

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Synchronization The TR DDS‐DP and DDS‐R typically require 30 to 90 seconds to synchronize. Once synchro‐ nized, the Status LED will turn ON green. If synchronization cannot be achieved, check the T/ R pair for open‐circuit or short‐circuit conditions or load coils. Connections All connections are made through the 50‐pin Amphenol connector on the backplane of the  Total Access 1500. See Table 5. Table 5. Total Reach Pair Location for Total Access 1500 Total Total Port 1 Port 1 Access Access T/R (P1) T/R (P1) 1500 Slot 1500 Slot 26 /1...
  • Page 17: Provisioning

    Provisioning Provisioning On initial installation, the TR DDS‐DP is provisioned according to the factory default settings.  False Loopback Immunity ADTRAN’s Protected Loopback family of channel units includes an algorithm compatible  with SARTS, Hekimian, TPI, and other test systems that virtually eliminate false latching  loopbacks. Immunity is automatically enabled at 64 kbps.  In addition, ADTRAN’s Protected Loopback family features a protected loopback mode for  further false latching loopback protection. Latching Loopback Latching loopbacks are always enabled except when temporarily disabled via the protect  loopback features. When 64 kbps is enabled, placing SW1-3 (PLB)  to OFF will permit the TR  DDS‐DP to respond to the legacy latching loopback sequence as described in TR62310 and  ANSI T1.107. At 64 kbps, placing  SW1-3  to ON, the TR DDS‐DP will enable ADTRAN’s  Protected Loopback mode. Control Protocol Remote access to provisioning and status information is accomplished using either ADTRAN  Digital System 6 Message protocol defined in Control and Diagnostic Procedures Practice,  Section 6032991‐6, or through the craft interface on the Total Access 1500 SCU. Digital System  6 is supported by the TPI 108/109 and 105 portable test sets and is supported by Hekimian  React 2001 Revision 1900 remote test system.  The TR DDS‐DP network elements comply with ANSI T1.107‐1995, “Digital Hierarchy Format  Specifications Annex G” which allows remote provisioning, querying, and performance  monitoring via in‐band control of network elements. NOTE The REACT 2001 GUI software Release 1.900 supports ANSI T1.107‐1995. Remote access is accomplished using a defined set of in‐band DS0 byte sequences similar to  the latching loopback sequence. Commands issued via the test system are recognized by the  individual channel unit which responds with the appropriate byte sequences. These in‐band  commands can be used to verify options via dialogs with REACT 2001, TPI 108/109 and TPI  105 test sets. Unit CLEI, serial number, provisioning, and performance information can be ...
  • Page 18: Provisioning And Status Ds6

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Provisioning and Status DS6 All configuration options can be remotely viewed or provisioned via DS6. The front panel  remote ( REM ) LED indicator flashes during DS6 control link establishment and remains ON  after the channel unit has been remotely provisioned. The newest provisioning will overwrite  any existing provisioning contained on the TR DDS‐DP. Time Slot Assignment The Total Access 1500 platform can have multiple time slots in the T1 data stream assigned to  each physical slot in the channel bank. The Total Access 1500 allows craft selectable time slots  using the electronic provisioning interface. AP-Switch If the channel unit has been remotely provisioned, the operator can alternate between remote  configuration and manual switch settings by pressing the momentary Alternate Provisioning  ( AP ) switch located on the front panel. If the channel unit is removed from the system, the  Total Access 1500 bank slot retains the last remote provisioning information. A similar TR  DDS‐DP placed in that slot will assume the same remote provisioning. REM Indicator The  REM  indicator remains ON when the channel unit is operating based on remote provi‐ sioning, and is OFF when operating on manual switches. If the channel unit has never been ...
  • Page 19: Options

    Provisioning Options Select the appropriate Option and Rate using circuit board switches  SW1  and  SW4  as illustrated in  Figure 2. Select options prior to board insertion. Figure 2. Option and Rate Selection Switches Protected Loopback (PLB) ADTRAN’s Protected Loopback supports the new proposed DDS latching loopback standard  in T1E1.2/99‐007R1. When Protected Loopback is enabled, the TR DDS‐DP will respond to  latching loopback when the idle code preamble is sent prior to the latching loopback sequence  specified in TR62310 and ANSI T1.107.  Protected Loopback prevents false latching loopbacks when the loopback sequence is  embedded in customer payload data. Test equipment should support T1E1.2/99‐007R1 to  perform testing at 64 kbps when protected loopback is enabled.  See Table 6 for the latching loopback sequence requirement when Protected Loopback is  enabled. Table 6. Protected Loopback Mode Requirement Sequence Function Byte Code # of Received Bytes Exit Data Protocol...
  • Page 20: A/B Signaling (A/B)

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide NOTE A minimum of 35 TIP bytes is required to disable established latching loopback. X = Donʹt Care bit. A/B Signaling (A/B) When A/B Signaling ( SW1-4 ) is OFF, the unit derives signaling from the incoming data stream.  When A/B Signaling is ON, the unit determines the state of the A and B Signaling bits using  signals present on the backplane of the channel bank. This method assumes that proper  signaling has been maintained throughout network tandems and cross connect systems. NOTE A/B Signaling option is only applicable when SW56 is selected; otherwise it is a “don’t care.” Quality Monitor (QM) When Quality Monitor ( SW1-5 ) is ON, the TR DDS‐DP monitors the incoming 2‐wireloop and  4‐wire customer interface data for errors. If excessive errors are detected, the unit blocks the  customer’s data transmission and transmits an alternating MOS (9Ah)/ASC (9Eh) trouble code  to the network. Customer data transmission is automatically restored when the trouble  condition is cleared. Rate Selection Select rate with dip switch ( SW4 ) by positioning the selected switch toward the inscribed rate.
  • Page 21: Testing

    Testing Testing The TR DDS‐DP is equipped with logic level bantam test access jacks that permit testing in  both directions using a portable test set. Latching DS0 and CSU loopback sequences and alter‐ nating CSU loopback sequences are supported.  Alternating loopbacks do not operate when the 64 kbps data rate is selected. Choose NEAR to  test toward the customer loop; choose FAR to test toward the T‐carrier. In the FAR direction, a  DS0 loopback sequence will loop the unit directly across the T‐carrier system. In the NEAR  direction, a DS0 loopback sequence will loop the unit directly connected to the portable test  set. NOTE If 64 kbps is selected, the unit will only respond to latching loopback sequences. Alternating sequences are not valid at this rate. 61180105L1-5C...
  • Page 22: Figure 3. Dds Trouble Codes

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide TR DDS-DP Trouble Code The TR DDS‐DP system provides a quick diagnosis in the case of a circuit condition where  continuity is broken. The trouble code type received by a tester determines whether the open  condition is occurring on the local loop or at the customer premises. In the event of a 2‐wire  DSL loss of signal, loss of sync, or an open condition caused by an open conductor or discon‐ nected 2‐wire loop, the TR DDS‐DP transmits an alternating MOS (9Ah)/ASC (9Eh) trouble  code into the network as shown in Figure 3. During a similar Out‐of‐Service condition at the  customer premises, the Total Reach OCU‐R transmits an ASC (9Eh) upstream into the  network Customer Premises Channel Bank Open 2-wire Loop Alternating MOS (9Ah)/ ASC (9Eh) DDS-DP OCU-R Customer Premises Channel Bank...
  • Page 23: Loopback Pushbutton (Remote Unit)

    Testing Total Reach DDS-DP DDS-R Test Unit Data Bidirectional Pass-Through loopback Figure 5. Total Reach DDS-DP Bidirectional Loopback Loopback Pushbutton (Remote Unit) The TR DDS‐DP initiates a loopback in response to the loopback pushbutton on the remote  unit (for example: DDS‐R ACE). refer to Figure 6.) When available, the pushbutton will allow  a field technician or craft personnel to conduct loop testing from the remote end independent  of the test center or CO. Remote unit pushbutton operation and LED indication are discussed  in the remote unit documentation. The TR DDS‐DP STATUS  LED will turn ON yellow in  response to this loopback. Total Reach DDS-DP Figure 6. Total Reach DDS-DP Response to DDS-R ACE LBK Button 61180105L1-5C...
  • Page 24: User Interface

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide User Interface This section provides detailed information on the following: • “Menu Structure” on page 14 • “Menu Navigation” on page 15 Menu Structure The menu structure for the TR DDS‐DP is a layered menu tree. Each layer of the menu tree is  displayed as a menu or a screen. Menus A menu is a display that provides numbered selections that are used to navigate to related  menus, modify provisioning information, or display information screens. A menu can contain  the following objects: • Menu Option: A menu option is indicated by a number which, when selected, navigates  the display to another menu layer or is used to change the option setting.  • Read‐only Field: A read‐only field displays information that cannot be changed. The  information displayed in a read‐only field can be static or can be automatically updated  by the unit. • Read‐write Field: A read‐write field displays information that, when selected, can be  modified. • Hot Key: A hot key is a key or combination of keys that are assigned to a function. Hot  keys are indicated by the required key(s) and a brief description (that is, “ ? ” ‐ Help).
  • Page 25: Menu Navigation

    Keyboard Description Command ACKSPACE This keyboard command deletes the character to left of the cursor during key‐ board input.  (or Return)  This keyboard command terminates input. NTER  (Control and r)  This keyboard command refreshes the display. (Control and z)  This keyboard command forces the terminal menu display to the top level.  (Escape) This keyboard command clears partial input or return to the previous menu. Remote Provisioning and Diagnostics TR DDS‐DP provides remote access to provisioning and diagnostics via ADTRAN Digital  System 6 Message (DS6) protocol. The TR DDS‐DP can also be accessed via the  craft interfaces  on the Total Access 1500 SCU. The following section provides detailed provisioning and  diagnostic information. • Control Protocol • Provisioning and Status DS6 • Electronic Provisisioning Control Protocol Remote access to provisioning and status information is accomplished using either ADTRAN  Digital System 6 Message protocol defined in Control and Diagnostic Procedures Practice, Section  6032991‐6, or through the craft interface on the Total Access 1500 SCU. Digital System 6 is  supported by the TPI 108/109 and 105 portable test sets and is supported by Hekimian React  2001 Revision 1900 remote test system. The Total Reach DDS network elements comply with  ANSI T1.107‐1995, “Digital Hierarchy Format Specifications Annex G” which allows remote  provisioning, querying, and performance monitoring via in‐band control of network  elements. NOTE The REACT 2001 GUI software Release 1.900 supports ANSI T1.107‐1995.
  • Page 26: Electronic Provisioning

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide commands can be used to verify options via dialogs with REACT 2001, TPI 108/109 and TPI  105 test sets. Unit CLEI, serial number, provisioning, and performance information can be  retrieved remotely using the Digital System 6 protocol. Provisioning and Status DS6 All configuration options can be remotely viewed or provisioned via DS6. The front panel  remote ( REM ) LED indicator flashes during DS6 control link establishment and remains ON  after the channel unit has been remotely provisioned. The newest provisioning will overwrite  any existing provisioning contained on the TR DDS‐DP. Electronic Provisioning The craft interface on the Total Access 1500 SCU may be used to change the default options  and obtain access module status through menu screens. To access the menu screens, connect a  terminal or a computer running a terminal emulation program to the front panel craft  interface ADMIN port using a standard male‐to‐female RS‐232 DB‐9 cable. Craft port settings  are as follows: • 9600 • No Parity • 8 Data Bits • 1 Stop Bit • No flow control Any change in provisioning from the Total Access interface will overwrite all existing remote ...
  • Page 27: Logging On To The Total Access 1500

    Remote Provisioning and Diagnostics Logging on to the Total Access 1500 To Log on to the Total Access 1500, complete the following steps: NOTE Account names and passwords can be provisioned to be case sensitive for a d d i t i o n a l   s e c u r i t y.   D e f a u l t   a c c o u n t s   a r e   A D M I N ,   R E A D O N LY, READWRITE, and TEST. The default password for each of these accounts is PASSWORD. The privilege to change passwords, account names, and privileges are included in the ADMIN account.
  • Page 28: Figure 8. Total Access 1500 Main Menu

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Once login is complete, the Total Access 1500 Main menu (Figure 8) is displayed.  Slot: SCU TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm Unacknowledged Alarms: NONE Total Access 1500 Main Menu 1. System Controller 2. Online LIU - [LIU A] 3. Offline LIU - [LIU B] 4.
  • Page 29: Main Menu

    Main Menu Main Menu Main Menu Main Menu The TR DDS‐DP Access Module main menu (Figure 9) is the access portal to all other operations  involving the TR DDS‐DP. The main menu options have several functions and submenus that  identify and provide access to specific operations and parameters. Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: NONE Total Reach DDS-DP Access Module 1. Configuration 2. Provisioning 3. Status 4. Loopbacks 5. Time And Date Selection: ‘?’...
  • Page 30: Configuration Screen

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Configuration Screen Configuration Screen Main Menu\Configuration Screen The Total Reach DDS‐DP Configuration Screen (Figure 10) lists information pertaining to the  unit, such as Name, CLEI Code, Part Number, and Software Revision. Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: NONE Total Reach DDS-DP Configuration Unit Name TR DDS-DP CLEI Code...
  • Page 31: Provisioning Menu

    Main Menu Provisioning Menu Provisioning Menu Main Menu\Provisioning Menu The Total Reach DDS‐DP Provisioning Menu (Figure 11) shows each possible option available  for  modification. Latching Loopback is enabled for all rates other than 64 kbps where it can be  set to “Protected.” Option 8 “OCU LBO to customer” is not available until the DDS‐DP is  synchronized with the Total Reach remote unit. Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: NONE Total Reach DDS-DP Provisioning 1. Data Rate 64 kbps 2. Secondary Channel Disabled 3. Error Correction Disabled 4.
  • Page 32 Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide The text “***INVALID CONFIGURATION***” as seen in (Figure 12) will appear on the screen  if the user selects provisioning prohibited by the unit. Invalid configurations include the  following combinations: 64 kbps Secondary Channel, 64 kbps Zero Code Suppression,  Hardware A/B Signaling at any rate other than SW56, SW56 Error Correction, and SW56  Secondary Channel. Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: NONE Total Reach DDS-DP Provisioning ***INVALID CONFIGURATION*** 1. Data Rate 64 kbps 2. Secondary Channel Disabled 3.
  • Page 33: Data Rate Menu

    Main Menu Data Rate Menu Data Rate Menu Main Menu\Provisioning Menu\Data Rate Menu The Data Rate  menu (Figure 13) allows the data rate to be changed by selecting one of the  data rates from the menu Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: NONE Data Rate 64 kbps 1. 64 kbps 2. 56 kbps 3. 19.2 kbps 4. 9.6 kbps 5.
  • Page 34: Status Screen

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide Status Screen Status Screen Main Menu\Status Screen The Total Reach DDS‐DP Status Screen (Figure 14) is used to quickly trouble shoot certain  problems based on the following criteria: Trouble Code to Network, Loop Receive Signal,  Quality Monitor Decision, Loop Circuit, Loopback. Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: Total Reach DDS-DP Status Trouble Code to Network Loop Receive Signal...
  • Page 35: Loopback Menu

    Main Menu Loopback Menu Loopback Menu Main Menu\Loopback Menu The Total Reach DDS‐DP Local Loopbacks Menu (Figure 15) initiates and releases local bidi‐ rectional loopbacks and remote unit loopbacks to the network. Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: NONE Total Reach DDS-DP Local Loopbacks 1. Bi-Directional DDS-DP Loopback [Not Active] 2. DDS-R Loopback to Network [Not Active] Selection: ‘?’...
  • Page 36: Dds-Dp Time And Date Screen

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide DDS-DP Time and Date Screen DDS-DP Time and Date Screen Main Menu\DDS-DP Time and Date Screen The Total Reach DDS‐DP Time and Date Screen (Figure 16) displays the time and date from  the Total Access 1500 SCU and then passes it on to the Total Reach remote unit.  The time and  date is used by the Total Reach remote unit to time‐stamp performance monitoring data at 15 ‐  minute and 24 ‐ hour intervals. Slot: 11 TOTAL ACCESS SYSTEM 1500 MM/DD/YY hh:mm:ss Unacknowledged Alarms: NONE...
  • Page 37: Deployment Guidelines

    Deployment Guidelines Deployment Guidelines The Total Reach DDS‐DP and DDS‐R use technology intended to eliminate the need for  repeaters and concerns over impairments caused by typical noise and bridged tap. Table 8  describes cable loss for the Total Reach DDS Nyquist frequency of 13.3 kHz, while Table 9  measures the DDS insertion loss. Listed below are the loop design guidelines for Total Reach  DDS: • All loops must be nonloaded. • Actual measured loss (AML) should not exceed 50 dB at 13.3 kHz (135 Ω termination), the  Nyquist frequency of Total Reach DDS.  NOTE The 50 dB AML limit includes 6 dB of signal margin to account for potential near‐end cross talk (NEXT) from other digital services that may be provisioned in the same binder group. • Loop length should not exceed 50 kft.  • Bridged tap length should not exceed 12 kft.  • Background noise level should not exceed 34 dBrn.  • Impulse noise level should not exceed ‐40 dBm, (+50 dBrn). Table 8. Cable Type and Temperature Loss Data @ 13.3 kHz Plastic Cable dB Loss/kft Paper Cable dB Loss/kft 19 Gauge PIC (0° F)
  • Page 38: Maintenance

    Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide NOTE Measure noise with 50 kbit weighting characteristic approximating a filter with a passband of 40 Hz to 30 kHz. Background noise level or impulse noise level is referenced from 56/64 kbps data rate in TR62310. Maintenance The TR DDS‐DP does not require routine maintenance for normal operation. Do not attempt  to repair the TR DDS‐DP in the field. Repair services are obtained by returning the defective  unit to ADTRAN. Refer to Appendix A, “Warranty” for further information. Specifications Specifications for theTR DDS‐DP are detailed in Table 10. Table 10. Specifications   Specification Description Electrical Total Power: 75 watts Maximum Current Draw: 0.070 A maximum @ –48VDC Maximum Heat Dissipation: 2.0 watts System Fusing: 5.0 amps GMT (one fuse for each unit) Tests Diagnostics: Self Test Environmental Operating Temperature: –40°C to 65°C...
  • Page 39: Warranty

    Appendix A Warranty Warranty and Customer Service ADTRAN will replace or repair this product within the warranty period if it does not meet its  published specifications or fails while in service. Warranty information can be found at  www.adtran.com/warranty.  ADTRAN Customer Care From within the U.S.:  1.800.726.8663 From outside the U.S.:  +1 256.963.8716 ADTRAN Sales Pricing/Availability:  1.800.827.0807 ADTRAN Technical Support Pre‐Sales Applications/Post‐Sales Technical Assistance:  1.800.726.8663 Standard hours: Monday ‐ Friday, 7 a.m. ‐ 7 p.m. CST Emergency hours: 7 days/week, 24 hours/day ADTRAN Repair/CAPS Return for Repair/Upgrade:  1.256.963.8722 Repair and Return Address Contact CAPS prior to returning equipment to ADTRAN. ADTRAN, Inc. CAPS Department 901 Explorer Boulevard Huntsville, Alabama 35806‐2807 61180105L-5C...