Omron CJ Series Operation Manual page 133

Machine automation controller analog i/o units
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

Device variable (name)
*_RateAlmSta
*_Ch1_L _RateAlmSta
*_Ch1_H_RateAlmSta
*_Ch2_L_RateAlmSta
*_Ch2_H_RateAlmSta
*_Ch3_L_RateAlmSta
*_Ch3_H_RateAlmSta
*_Ch4_L_RateAlmSta
*_Ch4_H_RateAlmSta
*_ErrSta
*_Ch1_Sens_ErrSta
*_Ch2_Sens_ErrSta
*_Ch3_Sens_ErrSta
*_Ch4_Sens_ErrSta
*_CJ_ErrSta
*_AdjPrdEnd_ErrSta
*_AdjPrevNotice_ErrSta
*_Conv_ErrSta
*1 If the Expansion Setting Parameters are not used, the Process Value HH (High High Limit) Alarm and Process
Value LL (Low Low Limit) Alarm will be 0.
*2 This value will be 0 if neither the Expansion Setting Parameters nor the Expansion Operation Data are used.
*3 This value will be 1 if an error occurs in the A/D conversion. If the error is not cleared after the Unit restarts or
the Controller is reset, including when the power is turned OFF and back ON, check whether there is a source
of noise nearby. For details, refer to 3-1-12 Error Processing.
CJ-series Analog I/O Units Operation Manual for NJ-series CPU Unit(W498)
Type
R/W
Data range
BYTE
R
16#00 to 16#FF
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BYTE
R
16#00 to 16#C3
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
BOOL
R
0 or 1
3 Isolated-type Universal Input Units
Data contents
A BYTE-type variable that includes the following
BOOL-type variables:
Input No. 1 Rate-of-change
Value L (low limit) Alarm
Input No. 1 Rate-of-change
Value H (high limit) Alarm
Input No. 2 Rate-of-change
Value L (low limit) Alarm
Input No. 2 Rate-of-change
Value H (high limit) Alarm
Input No. 3 Rate-of-change
Value L (low limit) Alarm
Input No. 3 Rate-of-change
Value H (high limit) Alarm
Input No. 4 Rate-of-change
Value L (low limit) Alarm
Input No. 4 Rate-of-change
Value H (high limit) Alarm
A BYTE-type variable that includes the following
BOOL-type variables:
Input No. 1 Input Error
Input No. 2 Input Error
Input No. 3 Input Error
Input No. 4 Input Error
Cold Junction Sensor Error
Zero/Span Adjustment Period
End
Zero/Span Adjustment Period
Notice
A/D Conversion Error
Bit
number
0: No alarm
00
1: An alarm
occurred
01
(Process value
exceeds set
02
value.) *2
03
04
05
06
07
Bit
number
0: Normal
00
1: Error
01
02
03
04
0: Adjustment
05
valid
1: Adjustment
period end *2
0: Adjustment
06
valid
1: Notice period *2
0: Normal
07
1: Error *3
3-29
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-pdc15Cj1w-ph41uCj1w-ad04u

Table of Contents