EN: Installation Sheet

Introduction
The EV1000 series includes models EV1012 and EV1012AM.
These detectors have a patented mirror, pyro, and signal
processing technology.
Note:
EV1012AM has not been evaluated by UL/cUL.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):
Direct sunlight on the detector
Strong draughts onto the detector
Heat sources within the detector field of view
Large animals within the detector field of view
Obscuring the detector field of view with large objects,
such as furniture
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
Installing two detectors facing each other and less than
50 cm (20 in.) apart

Installing the detector

Figure 7 legend
Item
Description
(1)
Standard connection (factory default)
(2)
Dual loop connection
P/N 146169999-10 (ML) • REV E • ISS 18JUN13
9A
9B
6
(2)
9A
1A
3B
7B
6
4
5B
(3) 5 curtains
6 m range
1B
2B
Item
Description
CP
Control panel
WT
Walk test
AM
Antimasking
D/N
Day/night
Rtest
Remote test
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, item 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, items 2 and 3).
3.
Fix the base to the wall between 1.8 m and 3.0 m (5.9 and
9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3). To install a pry-
off tamper, use position A or B.
Note:
Using the pry-off tamper has not been evaluated by
UL/cUL.
4.
Wire the detector (see Figures 3 and 7).
UL/cUL installations:
to National Electrical Code, NFPA70, and CSA C22.1,
Canadian Electrical Code Part I, Safety Standards for
electrical Installations.
5.
Select the desired jumper and DIP switch settings (see
Figure 5). See "Jumper settings" on page 4 for more
information.
6.
Remove the blinders and add the stickers, if required. See
"Configuring the coverage pattern" on page 5 for more
details.
(4) 7 curtains
6 m range
(6) 7 curtains
12 m range
All wiring must be made according
(5) 5 curtains
12 m range
(7) 9 curtains
12 m range
3 / 36