7
1
VE1120
J4
J3
CP
< 33 Ω
Normal
A
larm
VE1120
2
J4
J3
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0

EN: Installation Sheet

Introduction
The VE1120 series includes the VE1120 PIR and VE1120AM
PIR-AM motion sensors. They have a patented mirror, pyro,
and signal processing technology.
Note:
VE1120AM has not been evaluated by UL/cUL.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:
Direct sunlight on the detector
Strong draughts onto the detector
Heat sources within the detector field of view
Animals within the detector field of view
Obscuring the detector field of view with large objects,
such as furniture
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
P/N 146279999-5 • REV 00.01 • ISS 29JUL11
J4
J3
J4
J3
J4
J3
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0
VE1120AM
J4
J3
CP
< 33 Ω
Normal
A
larm
VE1120AM
J4
J3
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0
AM/TF
Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors)

Installing the detector

Figure 7 legend
Item
Description
1.
Standard connection (factory default)
2.
Dual loop connection
CP
Control panel
WT
Walk test
AM
Antimasking
D/N
Day/night
Rtest
Remote test
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, step 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, steps 2 and 3).
3.
Fix the base to the wall between 1.8 and 3.0 m (5.9 and
9.8 ft.) from the floor. For flat mounting use a minimum of
J4
J3
J4
J3
J4
J3
CP
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Short
0
AM/TF