Gate
Fault
Possible cause
*Bale does not
*Density too high density
come out
*Too wide windrow
*Declined field
*Gate does not
*Closing of stop valve
open
*Leakage or breakage of hydraulic
circuit
*Wrong adjustment of locking hook
*Disengagement of PTO
*Insufficient of power package oil
PTO shaft
Fault
Possible cause
*Abnormal
*Insufficient Lubrication
*Too much sharp angle of PTO shaft
Remedy
*Adjustment in according with"3-2-
4Adjustment of bale density"
*Making windrow in accordance with "3-3-
1 Method of windrow making"
*Ejection of a bale in flat place
*Opening of stop valve
*Remedy in accordance with "2-2-2-1
Inspection of hydraulic system gate
opening and closing
*Adjustment in accordance with"5-2-6
Adjustment of bale density detection link
*Engage PTO and eject bale while PTO is
running.
*Application of oil in accordance with"2-3
Lubrication spots table"
Remedy
*Application grease to sliding pipes,
spiders and mounting part of safety
cover
*Adjustment of tractor top link length,
lower link stabilizer and lower link upper
limit.
42