Troubleshooting the Four Slot Ethernet Cradle (Continued)
Table 9-3
Problem
During data communication,
no data was transmitted, or
transmitted data was
incomplete.

Single Slot USB Cradle

Troubleshooting the Single Slot USB Cradle
Table 9-4
Symptom
LEDs do not
Cradle is not receiving
light when
power.
wearable
Wearable terminal is not
terminal or
seated firmly in the
spare battery is
cradle.
inserted.
Spare battery is not
seated firmly in the
cradle.
Wearable
Wearable terminal was
terminal battery
removed from cradle or
is not charging.
cradle was unplugged
from AC power too
soon.
Battery is faulty.
The wearable terminal is
not fully seated in the
cradle.
Ambient temperature of
the cradle is too warm or
too cold.
Spare battery is
Battery not fully seated
not charging.
in charging slot.
Battery inserted
incorrectly.
Battery is faulty.
Cause
Wearable terminal removed
from cradle during
communication.
Incorrect cable configuration.
Ethernet connection error. Link
LED is not lit (see
Ethernet Cradle on page
Possible Cause
Ensure the power cable is connected securely to both the cradle
and to AC power.
Remove and re-insert the wearable terminal into the cradle,
ensuring it is firmly seated.
Remove and re-insert the spare battery into the charging slot,
ensuring it is firmly seated.
Ensure cradle is receiving power. Ensure wearable terminal is
seated correctly. Confirm main battery is charging.
View battery status by selecting
>
Power
Verify that other batteries charge properly. If so, replace the faulty
battery.
Remove and re-insert the wearable terminal into the cradle,
ensuring it is firmly seated.
Move the cradle to an area where the ambient temperature is
between 0 °C and 40 °C (32 °F and 104 °F).
Remove and re-insert the spare battery into the cradle, ensuring
it is firmly seated.
Ensure the contacts are facing down and toward the back of the
cradle.
Verify that other batteries charge properly. If so, replace the faulty
battery.
Maintenance & Troubleshooting 9 - 11
Replace wearable terminal in cradle and
retransmit.
See the system administrator.
See the system administrator. Probable
Ethernet connection error.
Four Slot
2-6).
Action
icon.
Solution
>
>
Start
Settings
Control Panel

Advertisement

Table of Contents
loading

Table of Contents