H7BR
REVERSIBLE +/- RANGE COUNTER OUTPUT OPERATION
H7BR-C
(Bold line represents present value; Output 2 operation applies for single preset models.)
Output Mode K Present value increments and decrements within the display's range. Output 1 goes ON for one-shot whenever
present value is equal to preset 1; Output 2 goes ON for one-shot whenever present value is equal to preset 2.
Comp.
Reset
999,999
Comp.
Preset 2
Preset 1
0
-999,999
Output 1
Output 2
Output Mode D Present value increments and decrements within the display's range. Output 1 is ON whenever present value is equal
to preset 1; Output 2 is ON whenever present value is equal to preset 2.
Comp.
Reset
999,999
Comp.
Preset 2
Preset 1
0
-999,999
Output 1
Output 2
Output Mode L Present value increments and decrements within the display's range. Output 1 is ON whenever present value is less
than or equal to preset 1; Output 2 is ON whenever present value is greater than or equal to preset 2.
Comp.
Reset
999,999
Comp.
Preset 2
Preset 1
0
-999,999
Output 1
Output 2
One-shot output
One-shot outputs can be set to 10, 50, 100, 200, 500 or
1,000 ms.
Instantaneous (equals) output
Reversible A, B, and C
Reversible A, B, and C
Reversible A, B, and C
Edge input
Sustained output/level input