H7BR
Standard Counter Output Operation (Continued)
H7BR-B
(Bold line represents present value; Output 2 operation applies for single-preset models.)
Output Mode R Present value display returns to reset start status after expiration of one-shot time period. Outputs are one-shot
and operate repeatedly. Output 1 latches ON at preset 1, and goes OFF after expiration of the one-shot period for Output 2. One-
shot time periods for Output 1 and 2 are independent.
Up
Reset
999,999
Preset 2
Preset 1
0
Output 1
Output 2
Output Mode K Present value runs continuously. Output 1 latches ON at preset 1, and goes OFF after expiration of the
one-shot period for Output 2. One-shot time periods for Output 1 and 2 are independent.
Up
Reset
999,999
Preset 2
Preset 1
0
Output 1
Output 2
Output Mode P Present value display does not change during one-shot time period, but reset start status returns as soon as preset
count is reached. Outputs are one-shot and operate repeatedly. Output 1 latches ON at preset 1, and goes OFF after expiration of the
one-shot period for Output 2. One-shot time periods for Output 1 and 2 are independent.
Up
Reset
999,999
Preset 2
Preset 1
0
Output 1
Output 2
One-shot output from Output 1
Sustained output
One-shot outputs can be set to 10, 50, 100, 200, 500 or 1,000 ms.
Down
Down
Down
One-shot output from Output 2
Sustained output
7
H7BR
Reversible A, B, and C
Reversible A, B, and C
Reversible A, B, and C