Omron H7BR Series Manual page 3

Hide thumbs Also See for H7BR Series:
Table of Contents

Advertisement

H7BR
OUTPUT MODES SUMMARY
Output
Description
mode
Single preset counter
N
Sustained output
F
Sustained output, overrun display
C
One-shot output
R
One-shot output, overrun display
K
One-shot output
P
One-shot output
Q
One-shot output, overrun display
A
One-shot output
D
Instantaneous output,
count value = preset
Sustained output, count value ≥ preset Sustained output 2, count value ≥ preset,
L
Sustained output, count value ≥ preset Sustained outputs when count values ≥ preset
H
K
One-shot output, count value = preset One-shot outputs, count value = preset
RATINGS
Supply voltage
Operating voltage range
Power consumption
Max. counting speeds (CP1, CP2)
Compensation and gate inputs
Reset
Batch count reset
Key protect
One-shot output
Inputs (count, compensation,
reset, batch count reset, gate)
Key protect input
Control outputs
Power supply for externally
Approvals
Ambient operating temperature
Storage temperature
Ambient operating humidity
Double preset counter
Sustained output 2, selectable sustained or one-shot output 1
Sustained output 2, selectable sustained or one-shot output 1
One-shot output 2, selectable one-shot or sustained output 1
One-shot output 2, selectable one-shot or sustained output 1
One-shot output 2, selectable one-shot or sustained output 1
One-shot output 2, selectable one-shot or sustained output 1
One-shot output 2, selectable one-shot or sustained output 1
One-shot output 2, selectable one-shot or sustained output 1
Instantaneous outputs when count value = preset
Sustained output 1, count value ≤ preset
100 to 240 VAC, 50/60 Hz or 24 VAC/12 to 24 VDC (permissible ripple: 20% max.)
85% to 110% of rated voltage
Approx. 10 VA at 50 Hz, 240 VAC, 6 W at 24 VDC (approx. 8 A surge current for 2 ms
upon power application)
30 cps, or 1, 5, or 10 kcps (separate setting for CP1 and CP2)
Set to the faster of the CP1 or CP2 max. counting speed
Min. pulse width for external reset: 1 or 20 ms, also manual reset
Min. pulse width: 20 ms
Response time: 1 second
10, 50, 100, 200, 500, or 1,000 ms (separate settings for presets 1 and 2)
No-voltage inputs
ON impedance:
ON residual voltage:
OFF impedance:
Voltage inputs
High level:
Low level:
Input resistant:
No-voltage input
ON impedance:
ON residual voltage:
OFF impedance:
Contacts: 3 A, 250 VAC, resistive load (p.f. = 1)
Transistor: Open collector; 100 mA at 30 VDC max. residual voltage 2 V max. (approx. 1 V)
12 VDC 160 mA, ±10% (5% ripple max.)
24 VDC 80 mA, ±10% (5% ripple max.)
UL/CSA/CE (EMC)
-10° to 55°C (14° to 131°F) (with no icing)
-25° to 65°C (-13° to 149°F) (with no icing)
35% to 85% RH
3
Applicable
counter series
H7BR-B
H7BR-B
H7BR-B
H7BR-B
H7BR-B
H7BR-B
H7BR-B
H7BR-B
H7BR-C
H7BR-C
H7BR-C
H7BR-C
1kΩ max. (approx. 2 mA when 0 kΩ)
2 V max.
100 kΩ min.
4.5 to 30 VDC
0 to 2 VDC
Approx. 4.7 kΩ
1 kΩ max. (approx. 2 mA when 0 kΩ)
1 V max.
100 kΩ min.
H7BR

Advertisement

Table of Contents
loading

Table of Contents