H7BR
SETTING ITEM TABLE
Mode
Setting item
Run
Set value 1,
mode
2
Batch count
set value
Set
Input mode
mode
Output mode Yes
Output time 1 Yes
(double
preset model
only)
CP1, CP2
count speed
Min. reset
time
Decimal
point
Prescale
value
Applicable model
Description
H7BR-B
H7BR-C
Yes
Yes
Compared to the present
value. Determines the
timing of the control out-
put according to the out-
put mode. The DISPLAY
key switches between
set value 1 and 2. (Double only.)
preset model only.)
Yes
No
Turns ON the batch out-
put when the preset
number of cycles have
been completed.
Yes
Yes
Determines the input mode Press keys 1 to 6 to change the displayed mode.
selecting from UP, DOWN
and REVERSIBLE modes.
Yes
Determines the control
output type. (Refer to
the Standard Counter
Output Operations and
Reversible +/- Range
Counter Output Operation
sections.) Determines
the output time for control
output (Output 2).
Yes
Determines the output
time of the control out-
put (OUT 1) for double
preset model counters.
Yes
Yes
Switches the count input
filter to protect against
errant counts due to
interference.
Yes
Yes
Determines the initial
signal width of the
external reset.
Yes
Yes
Determines the decimal
point position of the
present and set values.
Yes
Yes
Can calculate and display
a physical parameter
(volume, length, etc.)
from the present value.
For example, if one count
input represented a
movement of 0.02 mm,
the prescale value
would be 0.02.
Values from 0.001 to
99.999 are possible.
Setting procedure
Sequence when changing a digit using the increment
keys (1 to 6).
The +/- key changes the set value mark. (H7BR-C
Sequence when changing a digit using the
increment keys (1 to 6).
*H7BR-B only.
Press keys 1 to 6 to change the displayed mode.
H7BR-B
H7BR-C
Press keys 1 to 6 to change the Output 2 time.
(Applicable to output modes C, R, K, P, Q and A
only.)
Press keys 1 to 6 to change the displayed mode.
*H7BR-BW only.
Applicable to output modes C, R, K, P, Q and A only.
Press keys 1 to 6 to change the displayed mode.
The counting speed of CP1 or CP2, whichever is
faster, is set by the response speed of the gate
and compensation inputs, when the input mode
is set to REVERSIBLE C, make the counting
speeds of CP1 and CP2 equal.
Press keys 1 to 6 to change the displayed mode.
Move the decimal point position from left to right
with keys 1 to 6.
Change the value of the digits with the correspond-
ing keys, 1 to 5.
17
H7BR
Double preset model only.