Omron H7GP Datasheet
Omron H7GP Datasheet

Omron H7GP Datasheet

Total counter/time counter
Hide thumbs Also See for H7GP:

Advertisement

Quick Links

Total Counter/Time Counter
H7GP/H7HP
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions
or comments. Refer to Warranty and Application Considerations (page 20), and Safety Precautions (page 15).
High-visibility, IP66/NEMA4 Protection Total Counter/Time Counter Range
• IP66 (JEM standard IP66G: oil resistance) and NEMA4 protection standards.
• Switch between NPN and PNP operation.
• Both external and manual resets provided.
• Finger-protection terminal block cover prevents electrical shocks conforming to VDE0106/100.
• Conforms to EMC standards (EN61326).
• Conforms to IEC standards, and approved by UL and CSA.
• Wide power supply range.
• Six-language instruction manual provided.
H7GP
• 6-digit total counter
• 6-digit time counter
• DIN 48 x 24
H7@P Series
Total Counter/Time Counter
H7GP ..............................................................................
H7HP ..............................................................................
Common to Both Counters
Input Connections...........................................................
Safety Precautions..........................................................
Degree of Protection.......................................................
• 6-digit total counter/time counter
• 8-digit total counter
• DIN 72 x 36
Contents
Total Counter/Time Counter
H7HP
2
8
14
15
17
H7GP/H7HP
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron H7GP

  • Page 1 Total Counter/Time Counter H7GP/H7HP Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 20), and Safety Precautions (page 15). High-visibility, IP66/NEMA4 Protection Total Counter/Time Counter Range •...
  • Page 2: Ordering Information

    Compact Total Counters and Time Counters with Easy-to-read Displays and IP66G/ NEMA4 Water and Oil Resistance • High-visibility, negative transmissive LCD display with 8.5-mm- high characters and built-in red LED backlight at low power con- sumption. • Compact (80 mm) body. Model Number Structure ■...
  • Page 3: Specifications

    2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional.
  • Page 4 Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, four cycles each in three directions (8 minutes per cycle)
  • Page 5 Power Power Unused Unused Unused Unused supply supply Reset Count Reset Start Key protection Key protection Unused Unused input input input input input input NPN mode NPN mode PNP mode PNP mode H7GP Total Counter/Time Counter (DIN 48 x 24)
  • Page 6: Dip Switch Settings

    Operation ■ DIP Switch Settings H7GP-T/-TD Set all DIP switches before mounting the Counter to a control panel. All switches are set toward the display panel before shipping. Switch Item Function H7GP-C/-CD 3 (On right side Input mode Display side...
  • Page 7 Dimensions Note: All units are in millimeters unless otherwise indicated. H7GP-C H7GP-T Panel Cutouts M3.5 terminal screw Panel cutouts are as shown below (according to DIN43700). Note: 1. The mounting panel thick- ness should be 1 to 6 mm. 2. Water resistance will...
  • Page 8 12-mm-high characters for 8-digit models. • High-visibility, negative transmissive LCD display with built-in red LED backlight at low power consumption. • Compact (66 mm) body. • Switch 6-digit models between total counter and time counter operation. Model Number Structure ■ Model Number Legend...
  • Page 9 H7HP-C8 H7HP-C8D Rated supply voltage 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) External power supply 50 mA at 12 VDC 50 mA at 12 VDC...
  • Page 10 Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, four cycles each in three directions (8 minutes per cycle)
  • Page 11 Connections ■ Terminal Arrangement Note: 1. Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs. 2. Non-contact input is also available. AC Models H7HP-A H7HP-C8 External power supply External power supply 100 to 240 VAC 100 to 240 VAC 12 VDC 50 mA max.
  • Page 12 (see note 1) Display 0.0 h Note: 1. Display values are shown for full scale set to 99999.9 h. The count value will return to "0" when "99999.9" is exceeded. 2. Gate input is available only when H7HP-A settings are made.
  • Page 13 Dimensions Note: All units are in millimeters unless otherwise indicated. H7HP-A H7HP-C8 M3.5 terminal screw Terminal cover (provided) Panel Cutouts Panel cutouts are as shown below (according to DIN43700). Note: 1. The mounting panel thickness should be 1 to 6 mm.
  • Page 14: Input Connections

    (12 to 24 VDC) 12 VDC 12 VDC (12 to 24 VDC) (12 to 24 VDC) Reset, Count 1, Count 2, Start, and Gate Inputs Specification Sensor Sensor Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 2 VDC max.
  • Page 15: Usage Precautions

    Flush Mounting • Store the H7GP/H7HP within the specified ratings. If the H7GP/ H7HP has been stored at temperatures − 10 ° C or lower, let it stand for 3 hours or longer at room temperature before turning ON the The panel surface is water-resistive (conforming to NEMA 4 and power supply.
  • Page 16: Power Supplies

    When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Apply the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately.
  • Page 17 Spray water from all directions for one minute per m2 of external sur- Housing jets from all jets of water from all directions; face area and for a total time of no less than 3 minutes using the test directions limited ingress permitted.
  • Page 18 H7GP/H7HP Total Counter/Time Counter...
  • Page 19 H7GP/H7HP Total Counter/Time Counter...
  • Page 20 CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE...

Table of Contents