Summary of Contents for Intertec Data Systems SL DSETHERM DC.A

  • Page 1 Operating Instructions SL DSETHERM DC.A HOM225785099Ien-3 • 10/02/2020...
  • Page 2: Table Of Contents

    www.intertec.info Table of contents 1 General .................................. 3 2 Use ...................................  3 3 Special conditions for safe use.......................... 3 4 Explanation of symbols for warnings and signal words .................. 3 5 Safety information .............................. 4 6 Technical Data ................................  4 7 Installation................................
  • Page 3: General

    Operating Instructions SL DSETHERM DC.A General GB 50257-2014: Code for construction and acceptance of electric equipment on fire and explosion hazard elec- These operating instructions describe the safe and trical equipment installation engineering proper way to work with the device. The safety informa- GB 12476.2-2010: Electrical apparatus for use in the...
  • Page 4: Safety Information

    Operating Instructions SL DSETHERM DC.A Connecting cable AM Silicone hose cable, CAUTION notch- and oil resistant, 3 x 1,0 mm² Ø8,5 mm NOTICE Material Seawater-proof alu- This sign is warning about a hazardous situation which, minium, black anodized if not heeded, may lead to slight, reversible injury.
  • Page 5: Connection

    Operating Instructions SL DSETHERM DC.A Please make sure that the absolute heat transfer coeffi- short-circuit protection. When using a heater without in- cient of the surrounding housing is not smaller than 0.5 tegrated thermostat, the fuse protection can be selected W/K.
  • Page 6: Commissioning

    Operating Instructions SL DSETHERM DC.A Junction Junction box Option AM Option AM Heater Heater bn=brown bu=blue ye/gn=yellow/green bk=black gy=grey bn=brown bl=blue ye/gn=yellow/green bk=black gy=grey Illustration 4: SL...THERM with TAE Illustration 5: SL...THERM with TS Commissioning If the heater is installed in accordance with the notes in the Installation [}Page ...
  • Page 7: Troubleshooting

    Operating Instructions SL DSETHERM DC.A Functional and safety test intervals can be freely selec- NOTICE ted by the operator in accordance with the applicable regulations. Environmental damage may be caused if dis- Repairs may only be carried out by the manufacturer in posed of incorrectly! the factory.
  • Page 8: Certificate

    Operating Instructions SL DSETHERM DC.A If the information contained in this instruction manual You will find more detailed information in the manufac- should not be sufficient in any way, then INTERTEC turer warranty from INTERTEC for heating systems and would be glad to be at your disposal to provide further in- accessories.
  • Page 9 Operating Instructions SL DSETHERM DC.A HOM225785099Ien-3 Page 9 / 12 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...
  • Page 10 Operating Instructions SL DSETHERM DC.A Page 10 / 12 HOM225785099Ien-3 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...
  • Page 11 Operating Instructions SL DSETHERM DC.A HOM225785099Ien-3 Page 11 / 12 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...
  • Page 12 Operating Instructions SL DSETHERM DC.A Page 12 / 12 HOM225785099Ien-3 INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · +49 9445 9532-0 · info@intertec.info...