Intertec Data Systems SL VARITHERM DPA Operating Instructions Manual

Intertec Data Systems SL VARITHERM DPA Operating Instructions Manual

Advertisement

Quick Links

Operating Instructions
SL VARITHERM DPA
HOM500327947Ien-7 • 17/12/2020

Advertisement

Table of Contents
loading

Summary of Contents for Intertec Data Systems SL VARITHERM DPA

  • Page 1 Operating Instructions SL VARITHERM DPA HOM500327947Ien-7 • 17/12/2020...
  • Page 2: Table Of Contents

    www.intertec.info Table of contents 1 General .................................. 3 2 Use ...................................  3 3 Explanation of symbols for warnings and signal words .................. 3 4 Safety information .............................. 3 5 Installation accessories ............................ 4 6 Technical Data ................................  4 7 Installation................................ 4 8 Connection................................
  • Page 3: General

    Operating Instructions SL VARITHERM DPA General DANGER These operating instructions describe the safe and proper way to work with the device. The safety DANGER information and instructions given as well as the local This sign is warning about an extremely hazardous...
  • Page 4: Installation Accessories

    - 60 to + 180°C temperature Rated voltage/Operating voltage Switching capacity of fault 10 A / 275 V AC alarm (AM) Illustration 1: Example: SL VARITHERM DPA 250 T3 120 TS10 label Connecting cable Silicone hose cable, notch- and oil resistant, 3 x 1,5 mm²...
  • Page 5: Connection

    Operating Instructions SL VARITHERM DPA NOTICE Carefully remove When removing from the packaging and during transport, the connection line must not be stressed or bent. Free convection may not be impeded. You will find the minimum distances and installation position in the following figure.
  • Page 6 Operating Instructions SL VARITHERM DPA monitoring device needs to be used which switches off the supply as soon as the insulation resistance is no greater than 50 Ω per Volt of the rated voltage (refer also to DIN EN 60079-14; section 7.4).
  • Page 7: Commissioning

    Operating Instructions SL VARITHERM DPA Functional and safety test intervals can be freely selected by the operator in accordance with the applicable regulations. Repairs may only be carried out by the manufacturer in the factory. All components have to be kept clean and free of dust...
  • Page 8: 14 Eu Declaration Of Conformity

    Operating Instructions SL VARITHERM DPA Dipl.-Ing. Martin Hess, Managing Director NOTICE Further information and service Environmental damage may be caused if disposed of incorrectly! If the information contained in this instruction manual Electrical scrap and electronics components are subject...