Installation

Pump Setup

A fluid drain valve (AE) is required in your system to
help reduce the risk of serious injury, including
splashing fluid in the eyes or on the skin, and injury
from moving parts when you are adjusting or
repairing the pump.
The fluid drain valve (AE) helps relieve pressure in the
displacement pump, hose, and gun when shutting off
the pump. Actuating the gun to relieve pressure may
not be sufficient, especially if there is a clog in the
hose or the spray gun.
1. Apply thread sealant to all non-swivel connections
and install the outlet fitting (not supplied) and
required fluid drain valve (AE) to the pump outlet.
2. Use the colored pump identification bands
provided to identify the appropriate pump for your
material.
Red band A side
Blue band B side
NOTE: Use the provided labels to identify the ends
of the motor cables as A side and B side.
14

Install the Pump

1. Lubricate the o-ring on the outside of the bung
adapter (AF) and screw the bung adapter securely
into the bunghole (DB) of the drum.
K
BC
2. Insert the pump (K) through the bung adapter (AF)
and lock the bung adapter clamp (BC) into place.
AF
DB