Operation; Flush Before Using Equipment; Pressure Relief Procedure - Graco Core E1 Operation, Repair, And Parts

Electric transfer pump
Table of Contents

Advertisement

Operation

NOTICE
Do not operate if the pump lower and electric
motor are not properly coupled together or without
the clamp installed and tightened. Damage to the
equipment could occur.

Flush Before Using Equipment

To avoid fire and explosion, always ground
equipment and waste container. To avoid static
sparking and injury from splashing, always flush at
the lowest possible pressure.
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid
contaminating your fluid with oil, flush the equipment
with a compatible solvent before using the equipment.
Flush the equipment. See your Reactor 3 operation
manual.
3A8503C

Pressure Relief Procedure

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
1. Follow the Pressure Relief Procedure in your
Reactor 3 operation manual to relieve system
pressure.
2. Turn the TPC power switch (PS) to OFF.
3. Open the fluid drain valve (AE).