Operation
Changing Material Drums
NOTE: If the height of your ceiling or trailer prohibits
removal of the pump, remove the electric motor before
swapping out material drums.
Remove the Pump
1. Follow the Pressure Relief Procedure on page 15.
2. Loosen the bung adapter clamp (BC).
3. Carefully lift the pump (K) up and out of the bung
adapter (AF) and completely remove it from the
drum.
K
BC
Never use the power cord to lift or adjust the pump.
Lifting or adjusting the pump with the power cord can
damage it and cause injury from electric shock.
NOTE: To reinstall the pump, see Install the Pump on
page 14.
Remove the Electric Motor
1. Follow the Pressure Relief Procedure on page 15.
2. Loosen the clamp nut (DN) on the pump clamp
(DC), then remove the clamp.
16
3. Open the electric motor access door (DD).
4. Slide the electric motor away from the pump and
AF
NOTE: Use the mounting bracket (MB) to hang the
electric motor in a secure location when not in use.
remove the electric motor (DA).
MB
3A8503C