12.3 520RC, 520R2C and 520REC: pumphead position,
removal and replacement
The pumphead track can be fitted in one of two orientations to provide left or right
input/output port positions, and clockwise or anti-clockwise rotor rotation, whichever is
convenient. Please note, however, that tube life will be greater if the rotor rotates
clockwise; and that performance against pressure will be maximised if the rotor rotates
anti-clockwise.
To reposition the track
Isolate the pump from the mains power supply.
Open the pumphead guard as described under Opening the pumphead guard, below.
Remove the rotor as described under Rotor removal.
Undo and withdraw the four track-retaining screws using a slotted screwdriver.
Remove the track.
Relocate the track in the desired position. Replace and tighten the track-retaining screws.
Replace the rotor as described under Rotor replacement below.
Close the guard, pushing it fully home until the latch engages.
Page 21 of 47