3.1 One year warranty - 521P/RC 11.3 Operation and 521P/R2C models with air 11.4 Starting motors 11.5 Shutdown procedure 3.2 Two year warranty - 521CC 11.6 Specifications models with electric motors 11.7 Troubleshooting 4. Information for returning pumps 12. 520RC, 520R2C and 520REC pumpheads 5.
Watson-Marlow Bredel E-Manuals Page 2 of 47 1 Declaration of conformity When this pump unit is used as a stand alone pump it complies with: Machinery Directive 2006/42/EC, EMC Directive 2004/108/EC. 2 Declaration of incorporation When this pump unit is to be installed into a machine or is to be assembled with other machines for installations, it must not be put into service until the relevant machinery has been declared in conformity with the Machinery Directive 2006/42/EC.
Watson-Marlow Bredel E-Manuals Page 4 of 47 4 Information for returning pumps Equipment which has been contaminated with, or exposed to, body fluids, toxic chemicals or any other substance hazardous to health must be decontaminated before it is returned to Watson-Marlow or its distributor.
Watson-Marlow Bredel E-Manuals Page 5 of 47 6 Safety notes In the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained personnel after they have read and understood this manual, and considered any hazard involved. Any person who is involved in the installation or maintenance of this equipment should be fully competent to carry out the work.
Page 7
Watson-Marlow Bredel E-Manuals Page 7 of 47 521P/RC, 521P/R2C 521DFX/RLA, 521DFX/RL2A Note: The pumphead fitted to the 521DFX is the 501RLA, not he 520RC as shown here. file://M:\staging\pdfs-global\m-521-cc-gb-03.htm 14/12/2009...
Watson-Marlow Bredel E-Manuals Page 8 of 47 8 Unit installation Site the pump on a flat, horizontal, vibration-proof surface. allowing a free flow of air around it. Ensure that there is 1m of straight, flexible tubing before the pumphead inlet and after the pumphead outlet.
Page 9
Watson-Marlow Bredel E-Manuals Page 9 of 47 See the drawing below for drive motor connections, showing possible ancillary switches and connections. The ancillary switches should be rated to 220/240V 1ph 50Hz/60Hz. The Start contact should have a sprung return which will disengage following energisation of coils C1 and C1/1.
Watson-Marlow Bredel E-Manuals Page 10 of 47 9.2 AC three-phase motors: troubleshooting If the pump will not start make the following checks to determine whether servicing is required: Check that mains power is available to the pump. Check that the motor is connected in the correct Star/Delta configuration. ...
Page 11
Watson-Marlow Bredel E-Manuals Page 11 of 47 9.6 AC three-phase motors: gearbox maintenance - pump specifications Control range See motor nameplate Voltage/frequency See motor nameplate Power consumption See motor nameplate Full load current See motor nameplate Operating temperature range 5C to 40C, 41F to 104F Storage temperature range -40C to 70C, -40F to 158F Noise...
Watson-Marlow Bredel E-Manuals Page 12 of 47 10 Varmeca drives The Varmeca drive is an IP65 integrated electronically-variable speed drive fitted to a standard enclosure IP55 motor gearbox. Standard Varmeca drives are single-phase but three-phase Varmecas are available. Standard Varmeca drives are set up for manual control with the run command enabled. Current will be applied directly to the motor as soon as mains power is switched on.
Watson-Marlow Bredel E-Manuals Page 13 of 47 10.3 Varmeca drives: cables and protection devices Circuit breakers must be of the D-curve type suitable for a motor with an inverter. Comply with the size of protection (gl) fuses given in the table below. ...
Watson-Marlow Bredel E-Manuals Page 14 of 47 10.5 Varmeca drives: single phase connection diagram Before switching on the Varmeca-30 motor, check that electrical connections are correct and that any moving parts are mechanically protected. The Varmeca-30 must not be switched on with the protective cover removed. 10.6 Varmeca drives: keypad indicator light display Steady green light Mains connected...
Page 15
Watson-Marlow Bredel E-Manuals Page 15 of 47 10.7 Varmeca drives: Varmeca-30 specifications Power supply Single phase, 208V -10% to 240V +10%, 50/60Hz ±2% 110V -10% to 120V +10%, 50/60Hz ±2% Power range 0.25kW, 1/3HP Maximum hourly mains stop/starts Overload 150% of nominal current for 60 seconds, 10 times per hour Efficiency 97.5% motor efficiency...
Page 16
Watson-Marlow Bredel E-Manuals Page 16 of 47 10.8 Varmeca inverter factory settings The Watson-Marlow 521VI/RC and 521VI/R2C inverter default settings are listed in the table below. For more information on each parameter and its options, consult the Leroy- Somer Varmeca-30 operating instructions. Parameter Possible Parameter...
Watson-Marlow Bredel E-Manuals Page 17 of 47 11 Air motors The air motor is designed for air only. Do not allow corrosive, flammable or explosive gases or particulate material to enter the motor. Water vapour, oil-based contaminants or other liquids must be filtered out.
Watson-Marlow Bredel E-Manuals Page 18 of 47 11.3 Air motors: operation Do not drive an air motor with flammable or explosive gases nor operate the unit in an atmosphere containing them. Solid or liquid material leaving the motor can cause eye or skin damage. Keep away from the air stream.
Watson-Marlow Bredel E-Manuals Page 20 of 47 12.2 520RC, 520R2C and 520REC: good pump installation practice General recommendations The pump may be set up so that the direction of rotor rotation is clockwise or counter- clockwise, whichever is convenient. Please note, however, that for the 520R and 501RL pumpheads tube life will be greater if the rotor rotates clockwise;...
Watson-Marlow Bredel E-Manuals Page 21 of 47 12.3 520RC, 520R2C and 520REC: pumphead position, removal and replacement The pumphead track can be fitted in one of two orientations to provide left or right input/output port positions, and clockwise or anti-clockwise rotor rotation, whichever is convenient.
Page 22
Watson-Marlow Bredel E-Manuals Page 22 of 47 Rotor removal Remove any tubing from the pumphead. Open the flexible rotor cap in the centre of the rotor. Undo and withdraw the central locating screw using a slotted screwdriver. Pull the rotor hub off its dogged shaft.
Watson-Marlow Bredel E-Manuals Page 23 of 47 13 520RC, 520R2C and 520REC installation 13.1 Opening the pumphead guard Isolate the pump from the mains power supply. Unlock the pumphead guard by turning the guard fastener ¼ turn anticlockwise with a ...
Page 24
Watson-Marlow Bredel E-Manuals Page 24 of 47 Feed the tubing around the pumphead track, turning the rotor as necessary. Make sure the tubing is not twisted. Ensure that the second 225mm mark is adjacent to the inner edge of the upper tube clamp. ...
Watson-Marlow Bredel E-Manuals Page 25 of 47 13.3 520REC: fitting the drain port The drain port is an optional extra, supplied with the pumphead. It is strongly recommended that users fit it before the pump is operated. This may be done with the rotor in position or removed.
Watson-Marlow Bredel E-Manuals Page 26 of 47 13.4 520REC element loading 520RE tubing element pumpheads are factory-set to accept Watson-Marlow 2.4mm-wall tubing elements. Elements fitted with either quick-release industrial connectors or Tri-clamp sanitary connectors may be used; however, it is vital to match the pressure rating of the element with the pressure rating of the pumphead so that the correct roller- springing and occlusion settings are used.
Page 27
Watson-Marlow Bredel E-Manuals Page 27 of 47 520REC element loading procedure Note: The element loading procedure is the same for industrial (pictured) and sanitary elements. Select an appropriate Watson-Marlow 520RE tubing element, paying attention to pressure capability, bore size, tubing material and type of connector. See the table above for pressure ratings.
Watson-Marlow Bredel E-Manuals Page 28 of 47 13.5 520REC element connection Select suitable tubing to connect to the tubing element supply and discharge connectors. Check that its pressure rating is appropriate to the application. Sanitary ¾in Tri-clamp connectors Sanitary connectors are connected to a tubing system using Tri-clamps and EPDM gaskets. Hold the connector end of the supply or discharge tube against the element connector, ...
Watson-Marlow Bredel E-Manuals Page 29 of 47 14 520RC, 520R2C and 520REC maintenance Always isolate the pump from the mains power supply before opening the guard or performing any positioning, removal or maintenance activity. As part of regular cleaning and maintenance (and at least every three months), lubricate ...
Watson-Marlow Bredel E-Manuals Page 30 of 47 15 520RC, 520R2C and 520REC rotor settings 520RC, 520R2C and 520REC pumpheads are factory-set to give optimum tube life with Watson-Marlow tubing. Radial roller positions should not be adjusted in any circumstances as this will adversely affect pumphead performance and invalidate warranty. Tamper-proof rotor arm occlusion setting screws are fitted to warn operators from occlusion adjustment.
Watson-Marlow Bredel E-Manuals Page 32 of 47 17 Flow rates Pumping conditions For precise and repeatable performance it is important to determine flow rates under operating conditions for each new piece of tubing. When rotating counter-clockwise, 520R, 520R2 and 520RE pumpheads' flow rates are directly proportional to rotor speed.
21 Warning not to use pumps in patient- connected applications Warning These products are not designed for use in, and should not be used for patient- connected applications. 22 Publication history PB0339gb-02; m-521cc-gb-03.htm: Watson-Marlow 521CC First published 02 03. This edition 02 06. file://M:\staging\pdfs-global\m-521-cc-gb-03.htm 14/12/2009...
Watson-Marlow Bredel E-Manuals Page 47 of 47 23 Decontamination certificate In compliance with the UK Health and Safety at Work Act and the Control of Substances Hazardous to Health Regulations, you are required to declare the substances which have been in contact with product(s) you return to Watson-Marlow or its subsidiaries or distributors.