NOTE Wall mounting is certified for use in maritime applications.
Software Installation Information
For the NPort's configuration, the default IP address of the NPort is:
LAN: Static; IP = 192.168.127.254; netmask = 255.255.255.0.
NOTE If you have forgotten the NPort's IP address, use the Device
Search Utility (DSU) from your PC to locate the NPort. After
searching the LAN for NPort units, the DSU will display the IP
address of each unit.
You may log in with the password moxa to change any setting to meet
your network topology (e.g., IP address) or serial device (e.g., serial
parameters). For first-time use, click the Wizard in the left navigation
panel. The wizard will prompt you to configure the IP address, SSID,
and security mode. For other settings, use the factory defaults or
modify the settings for your application.
For software installation, download the relative utilities from Moxa's
website:
https://www.moxa.com/support/support_home.aspx?isSearchShow=1
•
Download the NPort Windows Driver Manager and install it as the
driver to run with Real COM mode of the NPort Series.
•
Execute NPort Windows Driver Manager; then map the virtual COM
ports on your Windows platform.
•
You may refer to the DB9 Male Ports pin assignment section to loop
back pin 2 and pin 3 for the RS-232 interface to carry out a self test
on the device.
•
Use HyperTerminal or a similar program (you may download Moxa's
program, called PComm Lite) to test whether the device is working.
Pin Assignments and Cable Wiring
RS-232/422/485 (Male DB9) Pinouts
PIN
RS-232
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
–
RS-422/RS-485 (4W)
TxD-(A)
TxD+(B)
RxD+(B)
RxD-(A)
GND
–
–
–
–
- 5 -
RS-485 (2W)
–
–
Data+(B)
Data-(A)
GND
–
–
–
–