ELECTRICAL SPECIFICATIONS

1. All wiring must comply with local and national electrical
codes and must be installed by a licenced electrician. If you
have any questions regarding the following instructions,
contact a licenced electrician.
2. Check available power supply and resolve any wiring
problems BEFORE installing and operating this unit.
3. For your safety and protection, this unit is grounded
through the power cord when plugged into a matching wall
outlet. If you are not sure whether your wall outlet is
properly grounded, please consult a licenced electrician.
4. The wall outlet (3- -pin) must match the plug (3- -pin) on the
power cord supplied with the unit. DO NOT use plug
adapters or extension cords. See (Table 1) for receptacle and
fuse information.
5. The rating plate on the unit contains electrical and other
technical data. The rating plate is located on the right side of
the unit. Make sure to use the correct power supply
according to the rating plate of your air conditioner.
COOLING CAPACITY
RATED VOLTS
AMPS
WALL OUTLET
FUSE SIZE
NOTE: 10K- -14K (Cooling only) including models
18K (Cooling only) including models
10K- -12K (with Heating) including models
NOTE: Check rating plate on your specific model for exact receptacle and fuse type.
RECEPTACLE AND FUSE TYPES
10K---14K
18K(Cooling only)
(Cooling only)
10K---12K(With heating)
125
15
15
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death and/or property damage.
Shut off electrical power to unit before installing or
servicing.
If the air conditioner has a serial plate rating of 115 volts
and up to and including 7.5 amps, the unit maybe on a fuse
or circuit breaker with other devices. However, the
maximum amps on all devices for that fuse or circuit
breaker can not exceed the amps of the fuse for the circuit
breaker.
If the air conditioner has a serial plate rating of 115 volts
and greater than 7.5 amps it must have its own fuse or
circuit breaker, and no other device or unit should be
operated on the fuse or circuit breaker.
If the air conditioner has a serial plate rating of 230 volts, it
must have its own fuse or circuit breaker, and no other
device or unit should be operated on the fuse or circuit
breaker.
23K
(Cooling only)
250
15
15
23K (Cooling only) including models
18K- -23K (with Heating) including models
4
18K---23K
(With heating)
250
250
20
30
20
30