Specifications Of Electrical Parts - Carrier 42NQV025M Service Manual

Air-conditioner split wall type
Table of Contents

Advertisement

6. SPECIFICATION OF ELECTRICAL PARTS
6-1. Indoor Unit
No.
Parts name
1
Fan motor
2
Thermo. sensor (TA-sensor)
3
Micro power module (T101)
4
Micro controller unit (IC81)
5
Heat exchanger sensor
6
Line filter (L01)
7
Diode (D01,D02,D03 and D04)
8
Capacitor (C03)
9
Fuse (F01)
10
Regulator IC (IC12)
11
Varistor (R21)
12
Louver motor
6-2. Outdoor Unit (38NYV025M, 38NYV025M-A)
No.
Parts name
1
SC coil
(Noise filter)
2
DC-DC transformer
3
Reactor
4
Outside fan motor
5
Fan control relay
Outside air temp.
6
sensor (TO sensor)
Heat exchanger temp.
7
sensor (TE sensor)
Dischenge temp.
8
sensor (TD sensor)
9
Terminal block (6P)
Fuse
10
11
Electrolytic capacitor
12
IGBT
13
Compressor
14
Compressor thermo.
15
Rectifier
16
4-way valve coil
Running capacitor
17
(for fan motor)
Type
AFS-220-20-4AR
µRM1260V
µPD780076GK-703-9ET-A
(TC-sensor)
SS11V-R06270
S5688J
EKMH401VSN470MP20S
FJL 250 V 3.15A
S7805PIC
TN R10V471K-T8
24BYJ48
Model name
L01
GET-04051
L03
GET-04052
SWT-72
CH-57-Z-T
SKF-240-20B-1
G5NB-1A
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-6B
For protection of switching power source
For protection of inverter input overcurrent
LLQ2G501KHUBTF
GT15J321
DA89X1C-23FZ
PW-2AL
D15XB60-4001
DS451155NPQB
– 19 –
FILE NO. SVM-07009
Specifications
AC Motor with 145°C thermo fuse
DC Motor Over Heat protection circuit
10 kΩ at 25°C
10 kΩ at 25°C
27 mH, AC 0.6A
47 F, 400 V
µ
3.15A, 250 V
5VDC, 0.5A
470V
DC 12V
Rating
0.6mH, 15A
2.0mH,10A
Primary side DC280V, Secondary
side 7.0 V x 1, 12 V x 1, 17V x 2
L=19mH, 10A
20W
Coil DC12V Contact AC250V-1.5A
10kΩ (25°C)
10kΩ (25°C)
62kΩ (20°C)
20A, AC250V
3.15A, AC250V
25A, AC250V
500µF, DC 400 V x 3 pieces
15A, 600
3-phases 4-poles 750W
OFF: 125 ± 4°C, ON: 90 ± 5°C
15A, 600V
AC220-240V
AC450V, 1.5µF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

38nyv025m42nqv025m-a38nyv025m-a

Table of Contents