Care And Maintenance; Troubleshooting Guide - Carrier KC_141P Installation And Operating Instructions Manual

Carrier air conditioner user manual
Table of Contents

Advertisement

Available languages

Available languages

CARE AND MAINTENANCE

When servicing the air conditioner, be sure to turn the mode switch
to the "OFF" position and disconnect the power cord from the
electrical outlet.
CAUTION
!
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
DO NOT use gasoline, benzine, thinner or other chemicals
on the air conditioner as these substances may cause
damage to the paint finish and deformation of plastic parts.
CAUTION
!
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
Never attempt to pour water directly in front of the unit as
this will cause deterioration of the electrical insulation.
If the air filter becomes clogged with dust, air- -flow is obstructed
and reduces efficiency. The air filter should be cleaned once a
month. More frequent cleaning may be necessary depending on
outdoor and indoor air quality.
Air Filter Removal
The air filter is located behind the air intake front grill.
To remove the air filter, open the air inlet grille and take out the air
filter.
To reinstall the air filter, reverse the above procedure.
Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution.
PROBLEM
Air conditioner will not operate
Inefficient or no cooling
Noisy unit
Odors
Water dripping outside
Water dripping inside
Ice or frost build --- up
NOTE: If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a licensed technician.

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE
No power to the unit.
Dirty air filter. Inappropriate capacity for
application. Blocked air flow. Power
interruption, settings change too quick-
ly, or compressor overload tripped.
Loose parts. Inadequate support.
Formation of mold, mildew, or algae on
wet surfaces.
Condensation run--- off is normal dur-
ing hot and humid weather
Unit is not properly angled to allow wa-
ter to drain outside.
Low outside temperature. Unit air filter
is dirty.
CAUTION
!
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage
and/or improper operation.
DO NOT forget to install the air filter. If the air conditioner
is left to operate without the air filter, dust is not removed
from the room and may cause your air conditioner to fail.
When the air filter inlet grille and cabinet are dirty, wipe
with lukewarm water (below 40_C/104_F). Use of mild
detergent is recommended
Cleaning the Air Filter
1. Remove dust clogged in the filter by tapping it or
vacuuming clean it.
2. Wash the filter well with lukewarm water below 40_C
(104_F) while rubbing lightly: To get better results, wash it
with soapy water or a neutral cleaning agent.
3. Rinse the filter well using clean water then dry completely.
End- -of- -Season Care
1. Operate the fan alone for half a day to dry out the inside of
the unit.
2. Turn off power and remove plug from all socket.
3. Clean filter.
4. Store in a dry location.
SUGGESTED SOLUTION
Check connection of power cord to power source. Check
fuse or circuit breaker. Set FAN CONTROL to position other
than "OFF".
Clean or replace air filter. Check with dealer to determine
proper unit capacity for application. Remove obstruction
from grill or outdoor louvers. Let fan run to restart compres-
sor (in approximately 10 minutes).
Tighten loose parts. Provide additional support to unit.
Drain plug and drain base pan. Replace drain plug. Clean
unit thoroughly. Remove
Add flexible tubing to redirect water flow.
Unit must be installed on an angle for proper condensa-
tion run--- off. Check the unit and make adjustments.
When outdoor temperature is approximately 65 F or be-
low, frost may form when unit is in cooling mode. Switch
unit to FAN (only) operation until frost melts. Remove and
clean filter.
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kh_233pKc_223pKc_183pKc_233pKh_123p

Table of Contents

Save PDF