Rev. 01 12/21
Climatic ambient conditions
Air pressure (operation)
Temperature (operation)
Temperature (storage / transport)
Air humidity
Condensation
Whilst the operating panel has a robust design, the built-in components
are sensitive to excessive vibrations and/or shocks.
The operating panel must be protected from mechanical loads outside its
intended use.
The operating panel may only be transported in the appropriate
packaging and in the correct manner.
Before recommissioning
During storage and transport in cold weather, and in the event of extreme
temperature differences, ensure that no moisture is deposited on or inside
the unit (condensation).
If condensation is present, the unit may only be switched on after it is fully
dry.
SD card – data backup
The contents of the SD card can be saved on another medium in order to
be able to copy them back in case of card damage or data loss. Further
information can be found in the SD card user manual.
Some operating systems do not display individual files. This is
often the case with "autoexec.bat" files, for example.
When copying the data, make sure that all data is visible and
copied.
If in doubt, contact your IT department.
Inserting the SD card: See chapter "Inserting the SD card" on page 30.

Powder output/powder hose correction

The settings in the following example are carried out for each
gun individually!
Powder output corrections are made at the first start-up, after a service
work, after the solution of application problems, or by using different hose
diameters!
It is recommended to create a table with input fields (see "Example table
for powder output/powder hose correction"), so that, if a possible system
reset takes place, an access to these data can take place.
795 - 1080 hPa
max. 2000 m ü. NHN
± 0 – +50 °C (+32 – +122 °F)
-20 – + 60 °C (-4 – +140 °F)
Relative air humidity 10 - 95 %
Non-condensing
Maintenance / Repairs • 77