Maintenance 8. Maintenance Parts Replacement Procedures
(11) Remove the FG line of the M/C Power Cable.
(12) Disconnect the M/C Power Cable from the chassis front side.
(13) Remove the DMB from the chassis.
At this point, be careful not to touch the chassis and other parts.
RC90 Series Maintenance Rev.1
47